Edison Installation and Operation Manual
34
6.1.5 Auxiliary Battery System Level
The batteries’ voltage at full load is 25.2V and the minimum voltage to avoid damaging the
batteries is 22.5V. When the minimum battery voltage is reached, the stove will
automatically stop. The batteries must be recharged or the stove must be connected to a
power source.
Red
Indicates that the stove runs on the auxiliary battery system and the
batteries are 25% load (until 22.5V).
Yellow
Indicates that the stove runs on the auxiliary battery system and the
batteries are 50% load (until 23.6V).
Green
Indicates that the stove runs on the auxiliary battery system and the
batteries are at 75% load (until 24.5V).
Green
Indicates that the stove runs on the auxiliary battery system and the
batteries are full loads (until 25.2V).
Red
Indicates that the stove is powered, the batteries are 25% charged and
that they are charging.
Yellow
Indicates that the stove is powered, the batteries are 50% charged and
that they are charging.
Green
Indicates that the stove is powered, the batteries are 75% charged and
that they are charging.
Green Indicates that the stove is on and the batteries are full loads.
6.1.6 Adjusting the Combustion Level (Heat Output)
Press on the
pellet burn rate
adjustment button
Press + or -
to adjust
the burn rate
The stove’s input range goes from 10,000 BTU/h to 45,000 BTU/h. To change combustion
level, select the flame icon
on the main status page to display the “+” and “-”
combustion level settings.
Note: Input range may vary according to the type of pellets being used.
Even though your stove can burn a large variety of wood pellets, we strongly recommend
the use of high quality pellets to obtain maximum performance out of your stove (see
Section 5.2.1: Proper Fuel). When using lower quality combustible, a restrictive venting
system or using the stove in high altitude, you may need to adjust the “PILOT
ADJUSTMENT SETTING” and the “COMBUSTION ADJUSTMENT SETTING”. These two
(2) settings are available from the “SETUP” page.
Summary of Contents for DP00065
Page 82: ...Edison Installation and Operation Manual 82 15 Replacement Parts ...
Page 83: ...Edison Installation and Operation Manual 83 ...
Page 84: ...Edison Installation and Operation Manual 84 ...
Page 85: ...Edison Installation and Operation Manual 85 ...
Page 86: ...Edison Installation and Operation Manual 86 ...
Page 87: ...Edison Installation and Operation Manual 87 ...
Page 88: ...Edison Installation and Operation Manual 88 ...