![Dressler CESAR 1312 User Manual Download Page 64](http://html1.mh-extra.com/html/dressler/cesar-1312/cesar-1312_user-manual_2530911064.webp)
4-30
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
The
Interlock
interface is a 9-pin connector.
illustrates the
connector, and
describes each pin.
Figure 4-23. Interlock interface connector
Table 4-3. Interlock interface pin descriptions
Pin
Name
Reference
Pin
Signal
Type
Level
Description
1
INTERLOCK
INPUT (+)
3
Input
(floating)
5 V to 24 V
Contact closure to pin 2
via the user’s external
interlock loop. You may
also provide a 5 VDC to
24 VDC signal
referenced to pin 3 to
satisfy the interlock
2
INTERLOCK
OUTPUT
3
Output
(floating)
15 V
Contact closure to pin 1
via the user’s external
interlock loop. This
voltage output is floating
and has no reference to
ground.
3
INTERLOCK
RETURN (-)
floating
0 V
This is the return pin for
an external interlock
signal. This pin must be
used as return for the
external interlock
voltage, because the
interlock input (pin 1) is
floating and has no
reference to ground.
4
Connect to the shield of
the external interlock
cable.
Summary of Contents for CESAR 1312
Page 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Page 2: ......
Page 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Page 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Page 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Page 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Page 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Page 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Page 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...