CESAR 1312 (E)
Troubleshooting and Customer Support
6-7
CESAR™ 1312 Generator
Improper Tuning Adjustment
Dressler ships Variomatch units with standard tuning settings, which are
appropriate for most applications. In rare cases, the tuning parameters may
need to be adjusted for special applications. For information on adjusting
these tuning parameters, contact Customer Support.
Checking for and Resolving Errors and Warnings
The CESAR generator responds to many error and warning conditions. Errors
and warnings display on the front panel (errors appear in E
XX
form and
warnings in W
XX
form, followed by the message text). Errors are also
reported through command 223 on the
Host
)
Note:
This revision of the manual provides information associated with
software release 1.16. This version of the software included changes to
the error and warning messages. Please use an appropriate revision of
this manual for earlier versions of the software. If you do not have the
appropriate manual, contact Customer Support (see
). The unit reports the software revision level with
host port command
198
).
Error conditions always turn output off. If multiple error conditions exist, the
unit displays all errors. When operating in front panel control mode, you need
to reset the unit after the condition that caused the error has been resolved.
Once the condition is resolved, the front panel displays a
Quit
soft key, which
you press to reset the unit. The
Quit
soft key will not display until the error
condition is resolved. (In remote control mode, the unit automatically resets
after the condition that caused the error is resolved.)
Warning conditions do not shut output power off, and the warning message is
cleared when the condition that caused the warning condition is gone. The
front panel only displays one warning message at a time. Overload warnings
indicate that an operating limit has been exceeded, and the unit has reduced
output power to remain within the allowable range.
When an overload warning
is active, the unit is not meeting set point.
On the front panel, overload
messages end with an exclamation point.
The following sections describe error and warning messages, describe their
causes, and explain how to resolve them.
Summary of Contents for CESAR 1312
Page 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Page 2: ......
Page 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Page 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Page 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Page 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Page 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Page 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Page 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...