![Dressler CESAR 1312 User Manual Download Page 156](http://html1.mh-extra.com/html/dressler/cesar-1312/cesar-1312_user-manual_2530911156.webp)
5-36
Installation, Setup, and Operation
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
The
Recipe Settings
operating screen displays the actual position on the
ramp by a moving cursor point, in addition to the start and total running time.
If RF power is turned off during the
Recipe Settings
function, by hand, or
error, then the time stops. You may then:
•
Press
Quit
to stop.
•
Press
Restart
to start from the beginning.
•
Press
Continue
last
val
to continue at the same position you stopped at
before.
To Turn Off the Recipe Settings Feature Using the CESAR Generator Front
Panel:
1. Press the
Program
soft key.
2. Press
Next
until you see
Recipe Settings
on the display.
3. Press
Change
.
4. Press
Off
to turn off the feature.
5. Press the
Exit
soft key.
6. Press the
Execute
soft key.
For 8 minutes, a linear increasing power level from 150 W to 895 W.
For 6 minutes and 10 seconds, a linear increasing power level from 755 W to 1160 W.
For 7 minutes and 18 seconds, a linear decreasing power from 1160 W to 0 W.
For 22 minutes and 40 seconds, a linear decreasing power level from 895 W to 755 W.
Summary of Contents for CESAR 1312
Page 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Page 2: ......
Page 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Page 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Page 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Page 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Page 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Page 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Page 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...