4-18
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
8
21
RF FORWARD/
LOAD POWER
REGULATION
Digital
input
Use this signal to select
between RF forward power or
load power regulation. Apply
a positive DC input voltage of
4 V to 30 V to regulate on
load power. An open
connection to pin
8
or a DC
input voltage of less than
1.5 V causes forward power
regulation.
Load power is defined as
forward power minus
reflected power.
Note:
Pin 6 also changes the
regulation mode.
For a wiring diagram, see
.
9
Return for pin
22
See pin 22.
10
23
INTERLOCK
LOOP
Digital
input
To satisfy the interlock and
enable RF power in the
generator, close an external
loop from pin 23 to pin 10. A
resistance of 15
Ω
or less
across this pin closes the
loop. Pin 23 feeds this loop
via a current limiting circuit
(maximum 120 mA).
Alternatively, you can satisfy
the interlock by applying a
voltage of +4 V to +30 V
(referenced to ground) to pin
10.
For a wiring diagram, see
.
11
Return for pin
24
See pin 24.
12
Reserved
Table 4-2. 25-pin User Port pin descriptions (Continued)
Pin
Number
Return
Pin
Name
Signal
Type
Description
Summary of Contents for CESAR 1312
Page 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Page 2: ......
Page 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Page 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Page 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Page 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Page 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Page 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Page 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...