CON-2
IX.
(Continued)
TABLE 5A
G Diameter in millimeters for Disc Holder Identification. See Figure 18, for design details.
(Detail 1, is standard unless noted).
DALA Design
n/a
n/a
27.74
Detail 4
27.74
Detail 4
27.74
Detail 4
32.05
Detail 4
37.95
Detail 5
47.37
Detail 5
62.69
Detail 3
77.77
Detail 3
85.29
Detail 3
97.21
Detail 3
122.20
Detail 3
155.14
Detail 3
183.34
Detail 3
219.05
Detail 3
n/a
Liquid Trim
DL Design
20.6
24.66
27.94
Detail 2
27.94
Detail 2
29.64
Detail 2
32.31
37.87
49.0
57.50
70.15
77.57
88.39
110.77
140.87
166.70
199.14
n/a
Orifice
Size
D-1
E-1
D-2
E-2
F
G
H
J
K
L
M
N
P
Q
R
T
W
Low
Pressure
18.16
25.70
29.64
29.64
29.64
32.31
37.87
49.0
54.0
64.19
54.0
78.44
100.33
132.00
155.32
190.35
321.47
High
Pressure
18.16
23.42
26.21
26.21
26.21
1.183
35.41
1.780
54.0
64.19
54.0
78.44
100.33
132.00
155.32
190.35
321.47
LA Design
19.43
Detail 3
26.95
Detail 3
32.13
Detail 3
32.13
Detail 3
32.13
Detail 3
34.90
Detail 3
42.04
Detail 3
54.74
Detail 3
62.69
Detail 3
77.77
Detail 3
85.29
Detail 3
97.21
Detail 3
122.20
Detail 3
155.14
Detail 3
183.34
Detail 3
219.05
Detail 3
n/a
Low
Pressure
20.6
23.88
Detail 2
27.94
Detail 2
27.94
Detail 2
27.94
Detail 2
32.26
Detail 2
37.82
Detail 2
47.01
Detail 2
57.50
64.19
57.50
64.19
75.69
132.00
156.34
190.35
n/a
High
Pressure
20.6
24.66
33.53
26.21
26.21
30.05
35.41
45.21
57.50
64.19
75.69
65.28
75.69
132.00
156.34
190.35
n/a
Standard Disc Holder
O-Ring Disc Holder
Liquid Trim
LS Design
20.6
24.66
29.64
29.64
29.64
32.31
37.87
49.0
57.50
70.15
77.57
88.39
110.77
140.87
166.70
199.14
n/a
*For valve manufactured prior to June 1987, use dimension 20.57 mm for D-1 orifice.
Set Pressure Change Note: If it is necessary to change
the valve set pressure, it may be also be neces-
sary to change the disc holder. See Table 8 to
determine if the disc holder must be changed to
(from) low pressure from (to) high pressure when
changing the set pressure.
Media Change Note: If the protected media is changed
in form from a compressable fluid (air, gas or
steam), to a non compressable fluid (liquid),
change from a standard to a liquid trim disc
holder.
Bellows Conversion Note: If a conventional 1900
valve has a D, E, F, G, H, or J orifice disc holder,
the disc holder must be exhanged for a bellows
type holder.
O-Ring Conversion Note: If a standard metal seated
1900 valve is to be converted to an O-Ring valve,
then the disc holder must be replaced with an O-
Ring disc holder. If the valve has a “K” or larger
orifice, the standard disc holder may be ma-
chined to receive the oversized O-Ring disc.
Instructions for this procedure are provided with
the kit. O-Ring disc holders may be obtained with
the kit.