© DreamLine
All Rights Reserved
© DreamLine
All Rights Reserved
19
ENIGMA AIR ENCLOSURE Shower Enclosure manual Ver 1 Rev 4 062019
©2019 DreamLine. All Rights Reserved
**NOTE:
When installing to a stud,
drill a Ø1/4” hole up to the wood
and do not use a wall anchor.
*NOTE:
Installation of the Guide Rail
bracket into a stud or 2” x 6” wood
reinforcement is strongly recommended.
Fig 17
Fig 18
3
4
2*
1*
Ø1/4"
or 5/16”
tighten to
guide rail
tighten these set screws
to the wall bracket (6b)
and use to adjust the
guide rail to level
tighten to
guide rail
72-1/4”
!
The guide rail wall
bracket should be
centered in the
bracket as shown
to allow for vertical
adjustment both
up and down.
Note that the bottom of the
bracket is thicker than the top
and must be installed correctly
CL
(=)
(=)
top
bottom
!
2
1
3
17.
Hold the
Guide Rail Bracket (#06)
in the marked position
and use a center punch or small pencil to mark the wall
through the hole for drilling in the
Guide Rail Bracket (#06).
(Fig 17)
18. **
Drill a
Ø5/16”
anchor hole and insert
a
Ø5/16” Wall Anchor (#16)
.
Separate the
Guide Rail Bracket (#06)
components
(6a and 6b)
.
Install the
Guide Rail Wall Bracket (#06b)
to the wall using one
ST4.2 x 55
Countersunk Screw (#21). (Fig 18)