![Dream Maker Spas B6L Series Owner'S Manual Download Page 20](http://html1.mh-extra.com/html/dream-maker-spas/b6l-series/b6l-series_owners-manual_2529848020.webp)
Troubleshooting Guide
NO HEAT OR HEAT TOO LOW
P
ROBABLE
C
AUSE
#1 ......
Operating while spa cover is open.
ACTION .......................
Ensure that spa cover is properly closed.
P
ROBABLE
C
AUSE
#2
# .... Dirty filter
ACTION .......................
Remove filter cartridge and clean.
P
ROBABLE
C
AUSE
#3 ......
Adjustable jets closed or not fully opened.
ACTION .......................
Open all jets.
JETS WON’T COME ON
P
ROBABLE
C
AUSE
#1 ......
No power to spa control.
ACTION .......................
Check incoming power to spa.
P
ROBABLE
C
AUSE
#2
# .... Pump disconnected from control box.
ACTION .......................
Call dealer for recommended action.
P
ROBABLE
C
AUSE
#3 ......
Faulty pump or top control panel.
ACTION .......................
Call dealer for recommended action.
NO CONTROL DISPLAY OR FUNCTIONS
P
ROBABLE
C
AUSE
#1 ......
No power or improper voltage to spa control.
ACTION .......................
Have a licensed electrician check the voltage to spa.
P
ROBABLE
C
AUSE
#2
# .... Control box fuse blown.
ACTION .......................
Call dealer for recommended action.
P
ROBABLE
C
AUSE
#3 ......
Faulty top control panel.
ACTION .......................
Call dealer for recommended action.
LOW WATER FLOW
P
ROBABLE
C
AUSE
#1 ......
Dirty filter.
ACTION .......................
Remove filter cartridge and clean.
P
ROBABLE
C
AUSE
#2 ......
Jets not fully opened.
ACTION .......................
Open all jets.
P
ROBABLE
C
AUSE
#3 ......
Low water level.
ACTION .......................
Make sure water level in spa is correct.
NO AIR BUBBLES IN JET
P
ROBABLE
C
AUSE
#1 ......
Air control valve in the closed position.
ACTION .......................
Open air control valve. See page 7 or 11
P
ROBABLE
C
AUSE
#2 ......
Jet (s) in the closed position.
ACTION .......................
Open jet (s). See page 7 or 11
P
ROBABLE
C
AUSE
#3 ......
Faulty jet internal valve.
ACTION .......................
Call dealer for recommended action.
SPA IS LEAKING
P
ROBABLE
C
AUSE
#1 ......
Spa drain valve and cap partially open.
ACTION .......................
Ensure that drain valve and cap are fully closed.
P
ROBABLE
C
AUSE
#2 ......
Loose jet wall fitting.
ACTION .......................
See jet wrench instructions page.
P
ROBABLE
C
AUSE
#3 ......
Loose pump union (s).
ACTION .......................
Call dealer for recommended action.
NO SPA LIGHT
P
ROBABLE
C
AUSE
#1 ......
Burned out bulb.
ACTION .......................
Replace bulb (see page 17)
P
ROBABLE
C
AUSE
#2 ......
Light fuse blown.
ACTION .......................
Call dealer for recommended action.
P
ROBABLE
C
AUSE
#3 ......
Light harness unplugged from control box.
ACTION .......................
Call dealer for recommended action.
SLOW WATER DRAIN
P
ROBABLE
C
AUSE
#1 ......
Drain valve not fully opened.
ACTION .......................
Ensure that valve is fully open. See page 4 or 8.
P
ROBABLE
C
AUSE
#2 ......
Dirty filter or suction drain cover grate.
ACTION .......................
Remove filter cartridge or clean cover grate.
P
ROBABLE
C
AUSE
#3 ......
Kinked garden hose
ACTION .......................
Make sure that drain hose is fully extended and
placed in a flat or downhill position