17 of 73
Reference Manual ATOM one 4K mini
7 System Commands
7.1 rs232_baud <baud_rate>
Sets the baud rate for the RS232 terminal interface.
Supported Baud rates are 9600, 14400, 19200, 57600, 115200.
baud_rate
9600
14400
19200
57600
115200 (default)
7.2 rs485_baud <baud_rate>
Sets the baud rate for the RS485 terminal interface.
baud_rate
9600
14400
19200
57600
115200 (default)
7.3 rs485_addr <address>
Sets the address for the RS485 interface. It can not be set to the current value of the
broadcast address, an attempt to do so will return “FAIL”.
Value
Default
Minimal
Maximal
Device Address
0
0
99
Note: Make sure, that each address is unique on your RS485 bus system.
If you have an address conflict, it can be checked and changed any time via RS232
console, or by removing devices from the bus until the contention is solved.
The address 100 is reserved as a fail-safe address. All devices will always replay to
commands send over this address, as if it was their current device address. This can be
used to identify or change the device address if it has been lost.
7.4 rs485_bc_addr <address>
Sets the broadcast address for the RS485 interface. It can not be set to the current value