Chapter 1 DW-TY-9900 Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES)
Overview...........................................................................................................................................1
1.1 The Main Structure of ICP-AES...................................................................................................1
1.2 Brief Description of the Main Working Principle of ICP-AES......................................................1
1.3 Application.................................................................................................................................1
1.4 Instrument Composition and Working Principle........................................................................1
1.5 The Main Features.....................................................................................................................2
1.6 The Main Specifications............................................................................................................2
Chapter 2 Working Environment and Facility Requirements............................................................3
2.1 Working Environment.................................................................................................................3
2.1.1 Room........................................................................................................................................3
2.1.2 Suitable Operating Environment..............................................................................................3
2.1.3 Good Dust Prevention Measures.............................................................................................3
2.2 Power Supply and Auxiliary Material Configuration...................................................................4
2.2.1 Stable Power Supply System....................................................................................................4
2.2.2 Power Requirements................................................................................................................4
2.2.3 Grounding Requirements.........................................................................................................5
2.2.4 Gas Requirements....................................................................................................................5
2.2.5 Cooling Water Requirements...................................................................................................5
2.2.6 Exhaust Requirements.............................................................................................................5
2.3 Other Requirements for Laboratory...........................................................................................5
Chapter 3 Installation.......................................................................................................................6
3.1 Unboxing.....................................................................................................................................6
3.2 Installation..................................................................................................................................6
3.3 Acceptance.................................................................................................................................9
3.4 The Packing List.........................................................................................................................10
Chapter 4 Operation.......................................................................................................................12
4.1 Instrument Operation...............................................................................................................12
4.1.1 Boot Operation DW-TY-9900 ICP Follow the Steps Below.....................................................12
4.2 Software Function and Operation Interface.............................................................................13
Chapter 5 Daily Maintenance and Precautions.............................................................................27
5.1 Daily Maintenance...................................................................................................................27
5.2 Precautions for Turn On/ Off....................................................................................................28
5.3 Precautions for Daily Maintenance..........................................................................................29
Chapter 6 Common Fault Diagnosis Analysis and Elimination.......................................................30
Summary of Contents for DW-TY-9900
Page 16: ...15 In the new method enter the method name The following window appears determined...
Page 17: ...16 OK displays the following window...
Page 19: ...18 attenuation measurement standards measure the sample Selection Method...
Page 21: ...20 Automatic peak search...
Page 24: ...23...
Page 25: ...24 After you finish testing the standard point of exit to save Test sample...