3

Panel:

2)

Controller instructions:

(1) Cycles: display the number of cycles when it is a program segment;;

(2) Program segments: display the number of segments in program mode;
(3) Appointment time indicator: it lights when the appointment is turned on;
(4) Time: program segment time or fixed value timing time;
(5) Key lock;
(6) Reminder of temperature rise or fall;
(7) Measuring temperature;
(8) Set temperature;
(9) Alarm indicator: flashes when the machine is shut down or abnormal;
(10) Standby;
(11) Spare lights;
(12) Fan running indicator: it lights up when it starts running;
(13) Stop indicator: it turns on when the machine stops;
(14) Standby;
(15) Ultraviolet or illuminating lamp indicator: always on for illumination, flashing for UV
disinfection;
(16) Heating indicator light: on when heated;
(17) The refrigeration indicator: lights when there is refrigeration output and flashes when
refrigeration is delayed;
(18) Standby;
(19) Fan indicator light: lights up when the fan is workingt;

symbol: lights up when the

temperature unit is Celsius,

symbol: lights up when it is Fahrenheit;

3) Keyboard operation instructions

A: Key

: modify the parameter value; (long press for 5S to modify the existing running

time, with program has this function). Tap Lock or Unlock.

B: Shift key: Shift modification of parameter value, long press to start/stop temperature
auto-tuning, click to query ambient temperature.
C: SET key: Enter parameter setting,long press for 5 seconds to enter LK or exit
parameter setting.
D: Key

: Modify the parameter value, long press for 5 seconds to enter manual UV

Summary of Contents for DW-LBI Series

Page 1: ...gy Limited Chongqing Drawell Instrument Co Ltd Shanghai Drawell Scientific Instrument Co Ltd Chongqing Center Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqing China Shanghai Offic...

Page 2: ...I Application 1 III Technical Specifications 2 IV Installation requirements 2 V Operation Instruction 3 VI Wiring diagram 6 VII Malfunction handling 7 VIII Transportation and storage 7 IX After sales...

Page 3: ...he inside chamber can be cleaned regularly with dry cloth When the set temperature is lower than the room temperature the over temperature alarm will be generated if the door opening time is too long...

Page 4: ...be grounded The equipment shell should be grounded reliably and placed in a sheltered place from the sun cool and ventilated V Operation instruction Model DW LBI 80 DW LBI 150 DW LBI 200 DW LBI 250 D...

Page 5: ...always on for illumination flashing for UV disinfection 16 Heating indicator light on when heated 17 The refrigeration indicator lights when there is refrigeration output and flashes when refrigeratio...

Page 6: ...1 0 minutes 1 hour 0 Fn High and low fan switch 0 100 Start the low speed fan when the temperature is between the set value Fn and the set value Fn start the high speed fan when the temperature is out...

Page 7: ...ng integration time 1 3600S Integral action time constant the smaller the Iu the stronger the ability to correct the static error 240 d Heating differential time 0 3600S Differential action time const...

Page 8: ...value current measurement value current measurement value 0 cb Ambient temperature correction 60 100 0 cb actual ambient temp currently measured ambient temp 0 rl Temp lower limit setting 60 100 0 Th...

Page 9: ...e fan The meter is not corrected Correct the meter Note Maintenance operations shall be carried out by qualified personnel Please turn off the power supply before repairing VIII Transportation and sto...

Page 10: ...o change the data in the manual without prior notice The company has the final interpretation right 1 Biochemical incubator Machine 1 Set 2 User Manual Document 1 Copy 3 Fuse Spare parts 1pc 4 This pa...

Page 11: ...CO Ltd Add Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqing China Tel 0086 023 63268643 Shanghai Drawell Scientific Instrument Co Ltd Add Suite 1117 Lane561 XiuChuan Rd PuDong New...

Reviews: