Thanks for purchasing the equipment, please carefully read the manual before operating.

I. Precautions

When no lighting is needed in the chamber, please turn off the light so as not to affect

the temperature of the upper layer. Turn off the power supply before changing the light

tube.

Handle with care. The angle between the instrument and the ground shall not be less

than 45°.

There is a water outlet pipe behind the equipment. When the inside temperature is

low, a small amount of water will be discharged. Please use a pipe to connect to the

container or sewer.

Do not use acid or alkali and other corrosive articles to wipe the surface. The inside

chamber can be cleaned regularly with dry cloth.

When the set temperature is lower than the room temperature, the over temperature

alarm will be generated if the door opening time is too long, which is not a fault.

When change the fuse tube, please cut off the power sup

ply and replace the one

with the same model and specification.

Fans are installed in the operation room. Don’t put fingers or any objects into the

cover. Please cut off the power supply before maintenance.

Please turn off the power switch when stop using.

Please do not put inflammable, explosive or toxic, strong acid and strong alkali

articles in the working chamber of the instrument!

II

Application

It’s widely used for drying, baking, melting wax and sterilization in factories, mines,

universities, scientific research and laboratories.

III. Technical Specifications

Summary of Contents for DW-LBI Series

Page 1: ...gy Limited Chongqing Drawell Instrument Co Ltd Shanghai Drawell Scientific Instrument Co Ltd Chongqing Center Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqing China Shanghai Offic...

Page 2: ...I Application 1 III Technical Specifications 2 IV Installation requirements 2 V Operation Instruction 3 VI Wiring diagram 6 VII Malfunction handling 7 VIII Transportation and storage 7 IX After sales...

Page 3: ...he inside chamber can be cleaned regularly with dry cloth When the set temperature is lower than the room temperature the over temperature alarm will be generated if the door opening time is too long...

Page 4: ...be grounded The equipment shell should be grounded reliably and placed in a sheltered place from the sun cool and ventilated V Operation instruction Model DW LBI 80 DW LBI 150 DW LBI 200 DW LBI 250 D...

Page 5: ...always on for illumination flashing for UV disinfection 16 Heating indicator light on when heated 17 The refrigeration indicator lights when there is refrigeration output and flashes when refrigeratio...

Page 6: ...1 0 minutes 1 hour 0 Fn High and low fan switch 0 100 Start the low speed fan when the temperature is between the set value Fn and the set value Fn start the high speed fan when the temperature is out...

Page 7: ...ng integration time 1 3600S Integral action time constant the smaller the Iu the stronger the ability to correct the static error 240 d Heating differential time 0 3600S Differential action time const...

Page 8: ...value current measurement value current measurement value 0 cb Ambient temperature correction 60 100 0 cb actual ambient temp currently measured ambient temp 0 rl Temp lower limit setting 60 100 0 Th...

Page 9: ...e fan The meter is not corrected Correct the meter Note Maintenance operations shall be carried out by qualified personnel Please turn off the power supply before repairing VIII Transportation and sto...

Page 10: ...o change the data in the manual without prior notice The company has the final interpretation right 1 Biochemical incubator Machine 1 Set 2 User Manual Document 1 Copy 3 Fuse Spare parts 1pc 4 This pa...

Page 11: ...CO Ltd Add Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqing China Tel 0086 023 63268643 Shanghai Drawell Scientific Instrument Co Ltd Add Suite 1117 Lane561 XiuChuan Rd PuDong New...

Reviews: