D-1000B Heater
Operations & Maintenance
4.
OPERATIONS
CAUTION
Outdoor Use Only
4.1
General
The following chapter contains general information for operating the D-1000B
heater.
4.2
Control Panel
Operation of the D-1000B heater requires the usage of the control panel shown in Figure 4.1
1
3
2
5
4
II
I
Figure 4-1 - Control Panel Layout
Table 4-1 – Control Panel
Item Function
Description
1
Reset Button
Press the reset button to reset a lockout condition.
2
Power Switch
Three positioned switch, controls power to the unit.
3
Receptacle (Thermostat / CO
Detector)
Receptacle for thermostat usage, remotely.
4
Power Cord
120V, 60Hz.
5
Power Indicator Light
Illuminates when power is applied.
4.3
Start Up Procedure for Normal Operations
1. Remove protective fabric covers from each end and check for debris
2. Remove exhaust stack from heat outlet fabric cover.
3. Remove the operators’ manual and the thermostat / CO detector from the accessories bag.
4. Install exhaust stack.
5. Inspect fuel level and fill if necessary (use Diesel fuel or JP8).
6. Install the ducts and secure ducts by tightening strap. Minimize any bends. Keep ducts straight.
7. Connect heater to a 120V, 60Hz grounded power supply; ensure the power indicator light (5) is illuminated.
8.
If using
, the remote thermostat / CO detector connect the cord’s plug into receptacle (3), set the temperature,
and place the power switch (2) in the ON (II) position.
9. If
not
using the remote thermostat / CO detector, place the power switch (2) in the ON (I) position.
OPERATIONS
4-1
DHS SYSTEMS LLC
No rights are conveyed except as indicated in the legend on the inside front cover of this document.