5-14
Nominal Values
Nominal Values
Frequency,
voltage and
current settings
The Nominal Values screen allows users to enter values for frequency nominal line
voltage and current, or use the computed nominal values displayed on screen.
Continued on next page
Action...
Result...
STEP 1: Nominal Values screen
appears as users prepare the
instrument to record data. From
the Circuit Type Selection screen,
press Next to display Nominal
Values.
• If the computed nominal values
are accepted without change,
press
Next
. Go to page 5-16.
• To enter a new nominal
Frequency, Voltage and/or
Current value, press the
corresponding button and
proceed to Step 2.
• To set the properties to track
frequency of a monitored
system, press
Tracking
.
Proceed to Step 3 on page 5-14.
• Press
Cancel
to quit and return
to Start menu.
MARK110
NOTE: Make sure that the nominal values
computed by the PowerVisa are correct. Nominal
values are used as basis for setting default
thresholds and other parameters for circuit
monitoring.
STEP 2: Enter a new nominal
Frequency/Voltage/Current value
using the numeric keypad. Press
OK
to accept the new value.
• Press
...
...
t
to clear and retype
numeric values.
• Press
x1000
to multiply the
value by 1000.
• Press
Cancel
to retain previous
nominal values and return to
Nominal Values screen.
MARK110b
Summary of Contents for PowerVisa
Page 1: ...PowerVisaTM USER S GUIDE DRANETZ BMI 1000 New Durham Road Edison New Jersey 08818 4019...
Page 13: ...xiii Dranetz BMI PowerVisaTM...
Page 14: ......
Page 78: ...4 16...
Page 136: ...6 22...
Page 158: ...7 22...
Page 204: ...A 10...
Page 221: ...C 5 APPENDIX C Battery Specifications and Replacement Procedure Battery removal diagram...
Page 222: ...C 6...
Page 224: ...D 2...
Page 248: ...F 4...
Page 259: ...MARK201 LEVEL 200 Scope Mode MARK202 MARK205 G 9...
Page 269: ...MARK112b LEVEL 112_701 Advanced Options EN50160 Options MARK112c G 19...