34
CHAPTER 10 | MODIFICATION OF HUMIDITY RESULTS
The Dramiński TG Pro has humidity curves saved in its
memory They were developed on the basis of normal-
ized samples (their density was determined and the
mass of 1000 grains) Thanks to them the results are ac-
curate and repeatable However, it might happen that in
a certain year (due to different factors), the user’s harvest
is slightly different from the normalized grain and then de-
viations in humidity results may occur
These factors are as follows:
1 Shape of the grain and its ripeness (plumpness),
2 Variety qualities of the grain,
3 Level of contamination and tailings,
4 Level of devastation of the grain by pests and fungi
NOTICE!
Please, remember to compare the measurements only to
laboratory drying and weighing method but not to other
moisture meters because they may mislead you
The Draminski TG pro moisture meter enables introduc-
tion of modification of the measurements autonomously
When modification is carried out, each species is treated
separately When modification has been carried out, the
sign ”
*
” (asterisk) appears next to the species During the
measurements below the name of the tested species
there appears information about the value of modifica-
tion (the result automatically takes into consideration
the introduced modification), for example:
before
after
TG pro
22.1 0C
9.9%
Canola
Esc Start
TG pro
Mod:-0.3%
22.1 0C
9.6%
Canola
Esc Start
x
It is recommended to reset the default settings and if nec-
essary introduce new modification again When you reset
the default settings, the ”
*
” (asterisk) will disappear
Summary of Contents for Twist Grain pro
Page 3: ...2...
Page 4: ...3 EN INTRODUCTION...
Page 6: ...5 EN EQUIPMENT CHAPTER 1...
Page 8: ...7 EN CONSTRUCTION OF THE DEVICE CHAPTER 2...
Page 10: ...9 EN CHAPTER 2 EXTERNAL CONSTRUCTION APPROXIMATE DIMENSIONS 7 cm 7 5 cm 16 5 cm...
Page 11: ...10 CHAPTER 2 EXTERNAL CONSTRUCTION...
Page 12: ...11 EN KEYBOARD FUNCTIONS CHAPTER 3...
Page 14: ...13 EN HOW TO START THE DEVICE CHAPTER 4...
Page 18: ...17 EN NOTES FOR MEASUREMENTS CHAPTER 5...
Page 21: ...20 CHAPTER 5 NOTES FOR MEASUREMENTS...
Page 22: ...21 EN HUMIDITY MEASUREMENTS CHAPTER 6...
Page 26: ...25 EN EXTERNAL TEMPERATURE PROBE MEASUREMENTS CHAPTER 7...
Page 29: ...28 CHAPTER 7 EXTERNAL TEMPERATURE PROBE MEASUREMENTS...
Page 30: ...29 EN LIST OF AVAILABLE SPECIES AND HOW TO ADD NEW SPECIES CHAPTER 8...
Page 32: ...31 EN UPDATE VIA USB CHAPTER 9...
Page 34: ...33 EN MODIFICATION OF HUMIDITY RESULTS CHAPTER10...
Page 37: ...36 CHAPTER 10 MODIFICATION OF HUMIDITY RESULTS...
Page 38: ...37 EN MAIN MENU CHAPTER11...
Page 50: ...49 EN CHANGE OF BATTERIES CHAPTER12...
Page 53: ...52 CHAPTER 12 CHANGE OF BATTERIES...
Page 54: ...53 EN FINAL NOTES CHAPTER13...
Page 56: ...55 EN TECHNICAL DATA CHAPTER14...
Page 59: ...58...