![Dräger X-plore 3300 Instructions For Use Manual Download Page 25](http://html.mh-extra.com/html/drager/x-plore-3300/x-plore-3300_instructions-for-use-manual_2526849025.webp)
Maintenance
X-plore 3000
25
3.3.1
Negative pressure test
Seal both respiratory filters with your hands or an aid (e.g. a piece
of cardboard) and breathe in until a negative pressure is created
(refer to figure H). Hold your breath for a moment.
The negative pressure should be maintained. If not, adjust the
harness.
3.3.2
Positive pressure test
Seal the exhalation valve of the half mask and breathe out
forcefully (refer to figure J).
The half mask must NOT lift off your face. If the exhaled air
dissipates between face and mask body, adjust the harness.
4
Maintenance
4.1
Maintenance table
Operations required
Befo
re use
Af
te
r use
Every 6 mo
nt
hs
Every 2 years
Every 4 years
Inspection by wearer
X
Cleaning and disinfecting
X
X
1)
1)
For half masks in hermetically sealed packs. Otherwise every 6 months.
Visual and function check
X
X
2)
2)
Every 2 years if the half mask is packed in a hermetically sealed pack.
Replacement of exhalation valve disc
X