Use
158
X-plore 3000
3.2.3
Donning the half mask
1. Make sure that the correct respiratory filters are fitted.
2. For Dräger X-plore 3500 only: Close the clasp.
3. Draw the buckles of the head harness up to the end of the harness.
4. Pull the neck strap through completely until the buckles of the
head harness touch the yoke of the half mask.
5. Put the neck strap around your neck (refer to figure D).
6. Position the half mask over mouth and nose (refer to figure E).
7. Place the head harness over the back of your head, with the head
harness above your ears (refer to figure F).
8. Pull the ends of the top straps until the half mask rests tightly
against your face.
9. Tighten the top and bottom straps uniformly. If necessary, adjust
the harness again until the half mask rests against your face tightly
and comfortably.
10. Carry out a leak test.
WARNING
The bayonet catch must always be fitted on both sides! The
respiratory filter must be straight when locked in position!
Always use two respiratory filters of the same type.
If this warning is not heeded, poisoning or death can result.
NOTICE
for Dräger X-plore 3500:
By releasing the clasp, the half mask can be comfortably
placed on your chest (refer to figure G).
!
i
i