Cleaning Cautions:

Ÿ

Do not immerse the unit in water. It may damage the unit.

Ÿ

Disconnect the unit from the electrical outlet before cleaning.

Ÿ

Clean all necessary parts after each use as instructed in this guidebook.

4. OPERATING YOUR COMPRESSOR NEBULIZER

Ÿ

Fill the bottom section of the nebulizer with the medication prescribed by 

your  physician.  Be  sure  that  the  cone  is  tted  well  inside  the  bottom 

section.

Ÿ

Attach  mouthpiece  or  mask  per  your  choice  to  the  top  section  of 

nebulizer.

Ÿ

Attach one end of air tube to the base of the nebulizer.

Note:

 Prior to initial operation, the nebulizer should be thoroughly cleaned.

Ÿ

Plug the power cord into an appropriate electrical outlet. Make sure at this 

stage, the power switch is at “Off” status.

Ÿ

Gently  twist  the  top  part  of  the  nebulizer  counter  clockwise  to 

disassemble the nebulizer.

Ÿ

Attach the other end of air tube to the tube connector located on the front 

of the compressor.

Ÿ

Place your Compressor Nebulizer on a  at and stable surface. Be sure that 

you can easily reach the controls when you are seated.

Ÿ

Gently twist the top part clockwise to reassemble the nebulizer. Be sure 

the two sections  t well.

Place to  ll Medication

When treatment is  nished, shut off the unit and unplug it from the electrical 
outlet.

+ Unplug the unit from the electrical outlet.

+ Switch off the unit.

+  Wait  30  minutes  for  the  motor  to  cool  down  before  another 

treatment. Make sure the air openings are not obstructed. 

The compressor motor has a thermal protector, which will shut off the unit 
before the unit is overheated. When the thermal protector shuts the unit off, 
please:

5. CLEANING

It is recommended that the nebulizer, mouthpiece and mask be thoroughly 

cleaned with hot water after each use and cleaned with a mild detergent 

after the last treatment of the day. If your physician or respiratory therapist 

speci es a different cleaning procedure, follow their instructions.

Rinsing (After Each Treatment)

Ÿ

Gently twist the nebulizer to open it.

Ÿ

Rinse the nebulizer, mouthpiece and mask with water.

Ÿ

Reassemble the nebulizer when completely dry and put these parts in a dry, 
sealed container.

Ÿ

Dry them with clean so  towel or let it air dry.

Ÿ

Disconnect the air tube, nebulizer, mouthpiece and mask.

Disinfections:

Please  follow  the  following  steps  to  disinfect  your  nebulizer  unless 

otherwise  speci ed  by  your  physician.  It  is  suggested  that  the  unit  is 
disinfected after the last treatment of the day.

Ÿ

Use one-part white vinegar with three parts distilled water. Make sure 
mixed solution is enough to submerge the nebulizer, mouthpiece, and 
mask.

7

6

Summary of Contents for 407

Page 1: ...0 1 Thank you for purchasing the Dr Trust Compressor Nebulizer with Flow Adjuster 407 Please read this guidebook carefully to learn about the featuresofthisproductbeforestartoperatingit PleaseVisitdrtrustusa com 407forquickstartupguide 8 ABOUT US ...

Page 2: ...nd use of this product The system is compact and suitable for use with both children and adults in the home hospital and clinic settings etc It helps in the treatment of asthma allergies andotherrespiratorydisorders 2 PRODUCT IDENTIFICATION Ÿ Thenebulizerisintendedforsinglepatientuseinonetime Ÿ Any use of this product other than its intended use should always be avoided Note Ÿ Consult with your ph...

Page 3: ...nydamagedparts includingpowercord 4 Theunitshouldnotbeusedwhere ammablegas oxygenoraerosolspray productsarebeingused 3 If it has been dropped or submersed in water Promptly send it to a service centerforexaminationandrepair 5 Keep the air vents open Do not place the unit on a soft surface where the openingscanbeblocked Product Cautions Read all instructions carefully before use Failure to read and...

Page 4: ...nished shutofftheunitandunplugitfromtheelectrical outlet Unplugtheunitfromtheelectricaloutlet Switchofftheunit Wait 30 minutes for the motor to cool down before another treatment Makesuretheairopeningsarenotobstructed The compressor motor has a thermal protector which will shut off the unit before the unit is overheated When the thermal protector shuts the unit off please 5 CLEANING It is recommended ...

Page 5: ...gethe lterevery30daysorwhenthe lterturnsgray Ÿ Submergethesepartsinthevinegarandwatersolutionforthirtyminutes 6 SPECIFICATIONS Power AC 220V 50Hz Medica on Capacity 8ml Par cle Size 0 5 10um Current 0 8A Sound Level 65 dB A 1 meter away Average Nebuliza on Rate 0 25mL min 0 9 saline water Compressor Pressure Range 23 58 Psi 150 400KPa Standard Accessories Nebulizer Air Tube Adult Mask Child Storag...

Reviews: