background image

 
 

 

USER’S INSTRUCTIONS

IST-USO-0905109 

Rev. N. 03 dtd 09/03/2018  

IDP109 

Page 1 of 2 

 

K80E - AL1N

 

 

SUPPLIED AIR RESPIRATOR 

TYPE C CONTINUOUS FLOW CLASS 

 

Approved Respirator configuration: 
 

Part number 

Helmet 

Air control 

unit 

Breathing 

tube 

Air supply 

hose 

Belt 

Noise 

reducer 

Airflow 

indicator 

NIOSH APPROVAL 

0313190 

K80E 

0302021

 

AL1 

0303067 

0309116 

0309117 

0307020 

1614003 

0806026 

TC-19C-317 

 

1.  DESCRIPTION 

1.1  K80E  HELMET  (0302021):  It  is  composed  of:  a  fiberglass  shell 
covered with 3 coats of paint, the last one of which, the most external 
one,  is polyurethane; a polycarbonate visor; a polyamide collar which 
closes  efficiently  and  comfortably  round  the  wearer’s  neck;  a  head-
band adjustable from 53 to 63 cm (6-5/8 to 7-7/8 hat size). 
 
1.2  AL1  AIR  CONTROL  UNIT  (0303067):  It  is  composed  of  a 
diaphragm pressure regulator and connects the air supply hose to the 
breathing tube attached to the helmet. 
 
1.3  BREATHING  TUBE  (0309116):  It  is  composed  of  a  rubber  hose 
with couplings for connection to the K80E helmet. 
 
1.4 NOISE REDUCER (1614003): It is composed of various layers of 
synthetic felt in a copper housing. 
 
1.5 COMPRESSED AIR SUPPLY HOSE (0309117) It is composed of 
a  25  feet  long  rubber  hose  with  quick  disconnect  and  adaptor 
couplings.  Up  to  six  25ft.  hose  segments  may  be  connected  to  each 
other to form an air-line which is max. 150ft. long. The air supply hose 
connects  the  breathing  tube  to  an  air  source  supplying  clean 
breathable air. 
 
1.6  AIRFLOW  INDICATOR  (0806026):  composed  of  a  transparent 
tube with indicator ball inside. To check the airflow performance of the 
respirator it is supplied with, before each use. 
 

2.  TECHNICAL CHARACTERISTICS 

2.1  K80E HELMET:  
Shell : Fiberglass  - Face shield : Polycarbonate – Head suspension: 
Polyethylene – Face shield gasket: polyethylene foam. 
 
2.2  AL1 air control unit: 
Inlet pressure; minimum 70 psi (4,9 Bar) 
                       maximum 105 psi (7,4 Bar) 
 
Airflow:           > 200 Lpm (in the inlet pressure range) 
 
Noise level with hose and noise reducer;  < 80 Db  
 

3.  OPERATION 

3.1    The  air  control  unit  ,  supplied  with  breathable  compressed  air, 
provides  an  airflow  to  the  inside  of  the  helmet.  The  helmet  goes  into 
slight  overpressure  and  the  wearer  breathes  clean  air.  Expired  air  is 
expelled through the diaphragm valves. 
 

4.   USE 

4.1  For the protection of the eyes, head and respiratory system of the 
wearer.  These  respirators  can  be  worn  for  general  purpose 
applications  ,  including  pharmaceutical  manufacturing,  chemical  and 
pesticide  handling,  tank  cleaning,  spray  painting  and  other  industrial 
and  agricultural  applications  in  which  hazardous  compounds  are 
present. 
 
4.2  

LIMITATIONS/CAUTIONS

 

a)  These  respirators  are  not  approved  for  use  in  any  atmosphere 
immediately dangerous to life or health (IDLH). 
b)  Do  not  exceed  maximum  use  concentrations  established  by 
regulatory standards. 

c) These respirators can be used only when provided with breathable 
air  meeting the requirements for Type 1 gaseous air described in the 
ANSI/compressed  Gas  Association  Commodity  Specification  G-7.1 
Grade D or higher quality as specified in Federal regulations 42 CFR, 
Part 84.141 (b). 
d)  Use  only  the  pressure  ranges  and  hose  lengths  specified  in  these 
instructions. 
e) Failure to properly use this product may result in injury or death. 
f)  All  approved  respirators  shall  be  selected,  fitted,  used  and 
maintained  in  accordance  with  MSHA,  OSHA,  and  other  applicable 
regulations. 
g)  Never  substitute,  modify,  add,  or  omit  parts.  Use  only  the 
replacement  parts  listed  in  the  configuration  specified  by  the 
manufacturer. 
 

5.  USE INSTRUCTIONS 

5.1  HELMET SET-UP: 

 

Remove  protective  film  from  visor.  The  film  was  applied  to 
preserve the transparency of the polycarbonate until the moment 
of use. 

 

Position the noise reducer inside the helmet inlet connection. 

 

Fit the helmet on head steadily and adjust head band fit. 

 

Take helmet off and connect breathing tube (P/N 0309116), with 
the AL1 air control unit already attached, to the helmet by pushing 
tube  coupling  into  helmet  connection  and  turning  the  coupling 
clockwise. 

 
5.2  RESPIRATOR SET UP 

 

Connect  air  outlet  end  of  air  supply  hose  (P/N  0309117)  to  AL1 
air control unit. 

 

Connect  other  end  of  air  supply  hose  to  at  least  15  cfm  of 
compressed air as per Gas Association Commodity Specification 
G-7.1 Grade D or higher breathable air. 
 

5.3  WEARING INSTRUCTIONS: 
DON HELMET IN FRESH AIR ONLY 
- Buckle belt, with air control unit already fitted, around waist. 
-  Don  helmet  and  tighten  collar  drawstring  firmly  around  neck  by 
pushing on button and sliding up. The drawstring should be pulled as 
close as possible round neck to assure maximum closure but it should 
at all times feel comfortable and not restrict breathing in any way. 
 
5.4 AIR FLOW INDICATOR – INSTRUCTIONS AND PERFORMANCE 
CHECK 
Carry  out  the  airflow  performance  check  hereunder  before  each 
respirator use: 

 

Remove helmet connection breathing tube. 

 

Insert noise reducer in the bottom side of the flow indicator. 

 

Insert  airflow  indicator  onto  the  breathing  tube  and  position  so 
that the indicator is upright. 

 

Observe the position of the indicator ball inside the tube: 

o

 

If  the  indicator  ball  rises  above  the  indicator  line  (6 
cfm/170  l.p.m:  this  is  the  minimum  flow  required),  the 
respirator is ready for use. 

o

 

If  the  ball  fails  to  move  or  remains  on  or  below  the 
indicator line, insufficient airflow is being provided. This 
may be the result of a low pressure of the compressed 
air  line  or  a  overloaded  noise  reducer  or  a  damaged 
breathing  tube  or  air  control  unit.  Check  the 

Reviews: