18
In-Facility Time
The number of minutes (from 1 to 120) that a user will receive "In-Facility" status after
successfully accessing one door in the facility. Each BACTL manages countdowns after
receiving a broadcast.
Lights-On Time
(1-120)
The amount of time the lights will remain turned on, once the relay is latched.
COS Mode
Turn COS Mode ON or OFF. Once an open door alarm goes off, COS Mode will
automatically turn off the door alarm as soon as the door is closed. If COS Mode is OFF,
the door alarm will not reset until the unit is restarted or the user latches the appropriate
relay.
Elevator
Settings
Description
ID
The Identification number (1-4) of each Building Access Controlled device.
IP
The IP address of the profile-receiving unit.
Port
The On-the-Floor Port of the receiving unit.
On-the-Floor
Port
Listening port if BAC32 is controlling the elevator.