44
supply, to the condition of operation in positive pressure due to the first breath of
the operator. The cut section of the demand valve E400 AP/A is shown in figure 4.
It is also available in the version E400 APQ, equipped with a system for rapid
connection to the mask. To convert a threaded connector mask into the plug in
version you have to screw on the inlet of the mask a suitable adapter and tighten
appropriately. The system for quick connection to the mask is extremely rugged
and reliable, equipped with protection against the accidental release. The cut
section of the demand valve E400 APQ is shown in figure 5.
The DIABLO models are available with either demand valve detachable from the
pressure reducer (fitted with quick couplings on medium pressure hose) or non-
detachable (without quick couplings on medium pressure hose).
5.3
Mask
DIABLO series SCBA have been tested and certified with the following masks:
Model
Connector
Code
C607 SP/A
M 45X3
4333.3007
C607 SP/A SIL
M 45X3
4333.3008
C607 SP/A ESA
DIN 58600 4333.2028
C607 SP/A ESA SIL
DIN 58600 4333.2022
SFERA SP/A
M 45X3
4333.3004
SFERA SP/A SIL
M 45X3
4333.3001
SFERA SP/A ESA
DIN 58600 4333.2026
SFERA SP/A ESA SIL
DIN 58600 4333.2024
C607 SP/A Ex SIL (*)
M 45X3
4201.0658
C607 SP/A Ex (*)
M 45X3
4201.0657
SFERA SP/A Ex (*)
M 45X3
4201.0659
SFERA SP/A Ex SIL (*)
M 45X3
4201.0660
IDEA SP/A (**)(***)
M 45X3
4333.4000
IDEA SP/A SIL (**)(***)
M 45X3
4333.4003
IDEA SP/A ESA (**)(***)
DIN 58600 4333.4002
IDEA SP/A ESA SIL (**)(***) DIN 58600 4333.4005
(*) ATEX (Ex) models only.
(**)Atex class IIB
(***) SCBA type I only (extension certification to type II in progress)
Note:
the specific information concerning the chosen mask is contained in a
separate manual enclosed in the SCBA package.
5.4
Cylinder
The cap, at the connector side is enamel coated in 90° sectors alternately white
and black, according to applicable regulations (Ministerial Decree of 12/09/1925
Item 18). The cylinders are in accordance with the national regulations of the
country in which they are marketed and are accompanied by a certificate of
testing and documentation required. All data required by the law regarding the
identification of the cylinder is present on the cylinder. The cylinder, as an integral
part of the SCBA, is located on the back of the user with the connector facing