A5
INSTALLATION
IN GENERAL
See “Warnings” and “Distances to respect for the installation”.
Take off the packaging material with care. Take off all the material used for packing and accessories.
Bolt the oven to the floor using the 5 bolts included with the oven. Seal the unit on the floor with
silicone. Install the draft hood on the chimney. Verify every adjustments and correct it if
necessary. Install the hood covering the top front of the oven.
Each unit is set up to be used with the type of gas and electrical supply specified on the nameplate
fixed on the front of the oven.
The installation must be conform with the National fuel gas code ANSI Z223.1-XX and CAN/CGA-
B149-XX, Gas Installation Code and local Codes where applicable. Refer to last edition year for
XX.
The oven's combustion system consists of a very safe gas burner certified in accordance to the
American Gas Association Standard in USA and with the Canadian Gas Association in Canada.
1. To the certified gas technician
The burner installed on DOYON gas fired ovens is set up and adjusted at the plant for a first
class operation. It is nevertheless necessary to verify on site the pressure at the burner input.
The following table indicates the pressures that must be set up to remain conform to the AGA
standards or CGA.
TLOIG
GAS TYPE
ALTITUDE
(FT)
INPUT
(BTUH)
REGULATOR
INPUT
PRESSURE
(Water column
inches)
BURNER
INPUT
PRESSURE
(Water column
inches)
BURNER
ORIFICE SIZE
(DMS)
Propane
0-2000 USA
200,000
11,0
7,5
# 15 drill
Propane
0-4500 CAN
200,000
11,0
7,5
# 15 drill
Natural
0-2000 USA
200,000
7,0
3,5
19/64
Natural
0-4500 CAN
200,000
7,0
3,5
19/64
Summary of Contents for TLOIG
Page 20: ...A18 ...
Page 23: ...SECTION B DIMENSIONS ...
Page 24: ...B1 ...
Page 25: ...B2 ...
Page 26: ...B3 ...
Page 27: ...B4 ...
Page 28: ...B5 ...
Page 29: ...B6 ...
Page 30: ...B7 ...
Page 31: ...B8 ...
Page 32: ...B9 ...
Page 33: ...B10 ...
Page 34: ...B11 ...
Page 35: ...B12 ...
Page 36: ...B13 ...
Page 37: ...B14 ...
Page 38: ...SECTION C BURNER AJUSTEMENT ...
Page 39: ...C1 ...
Page 40: ...SECTION E COMPONENT PARTS ...
Page 41: ...E1 ...
Page 43: ...E3 ...
Page 45: ...E5 ...
Page 46: ...E6 ...
Page 47: ...E7 ...
Page 48: ...E8 ...
Page 49: ...E9 ...
Page 51: ...E11 ...
Page 53: ...SECTION F CONTROL PANELS ...
Page 54: ...F1 CONTROL PANEL 120V 208V 3PH 120V 240V 3PH ...
Page 55: ...F2 ...
Page 57: ...F4 CONTROL PANEL 220V 1PH 50hZ ...
Page 58: ...F5 ...
Page 60: ...F7 CONTROL PANEL 120V 208V 3PH WATLOW 120V 240V 3PH WATLOW ...
Page 61: ...F8 ...
Page 63: ...SECTION G ELECTRIC SCHEMATICS ...
Page 64: ...G1 ...
Page 65: ...G2 ...
Page 66: ...G3 ...
Page 67: ...G4 ...
Page 68: ...G5 ...
Page 69: ...G6 ...
Page 70: ...G7 ...