A-4
DISTANCES TO RESPECT
A)
Back and sides of the oven: 1 inch.
B)
Top of the oven: a clearance of 12 inches to the ceiling must exist to permit adequate venting
of the exhaust pipe and hot parts and to give proper access to a technician.
The draft hood must have a clearance of 2 inches minimum all around.
C)
Floor: 4 inches minimum.
D)
Sides of the oven: do not install other than easily removable equipment for service and
maintenance (not closer than 1 inch).
E)
It is recommended to have a certain length of water pipe, electric cable and gas pipe between
oven and wall to help gain access for service.
Summary of Contents for JA8G
Page 44: ...B 1 SECTION B COMPONENT PARTS PIÈCES COMPOSANTE JAOP8G FRONT VIEW JAOP8G VUE DE FACE B 1 ...
Page 46: ...B 3 JAOP8G RIGHT SIDE VIEW JAOP8G VUE DE CÔTÉ DROIT B 3 ...
Page 48: ...B 5 JAOP8G BACK VIEW JAOP8G VUE ARRIÈRE B 5 ...
Page 50: ...C 1 SECTION C CONTROL PANELS PANNEAUX DE CONTRÔLE 1PH 120V WITH ZELIO 1PH 120V AVEC ZELIO C 1 ...
Page 51: ...C 2 1PH 120V WITHOUT ZELIO 1PH 120V SANS ZELIO C 2 ...
Page 52: ...C 3 120 208 240V 1PH WITH ZELIO SIMPLE 120 208 240V 1PH AVEC ZELIO SIMPLE C 3 ...
Page 53: ...C 4 120 208 240V 1PH WITHOUT ZELIO SIMPLE 120 208 240V 1PH SANS ZELIO SIMPLE C 4 ...
Page 54: ...SECTION D BURNER ADJUSTEMENTS AJUSTEMENT DU BRÛLEUR NATURAL GAS GAZ NATUREL D 1 ...
Page 55: ...PROPANE GAS GAZ PROPANE D 2 ...
Page 56: ......
Page 57: ......
Page 58: ...NOTES ...