The customer must install a manual shut off valve at the end of the gas supply pipe near the burner
which is approved by the American Gas Association Standard in the United States and with the
Canadian Gas Association in Canada.
Exhaust: A draft hood is provided with the unit and it must be used when the chimney is directly
connected to a gas vent pipe. The exhaust pipe must be certified for use of gases.
Clean the air contained in the gas supply pipe at the installation to insure a successful firing on the
first try. The gas pipe sealing compound tightness must be verified using a solution of water and
soap prior to firing the unit.
WARNING
Make sure not to obstruct the overpressure opening on the gas regulator.
NOTE:
If there's any modification done to the system or change of the type of gas used, make
sure that the regulator pressure of the burner is adjusted as recommended in this
manual.
2. To the electrician
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
WARNING
The electrician must make sure that the supply cable does not come in contact with the
oven top which becomes hot.
3. To the plumber
This equipment is to be installed to comply with the applicable federal, state or local plumbing
codes.
Connect the steam system (1/4 NPT) to the cold water distribution network.
We highly recommend a water softener to eliminate minerals in the water. We suggest you to use
CUNO # CFS6135 (Doyon part number PLF240).
WARNING
Do not adjust the needle valves, it has been done at the factory.
Summary of Contents for JA8G
Page 44: ...B 1 SECTION B COMPONENT PARTS PIÈCES COMPOSANTE JAOP8G FRONT VIEW JAOP8G VUE DE FACE B 1 ...
Page 46: ...B 3 JAOP8G RIGHT SIDE VIEW JAOP8G VUE DE CÔTÉ DROIT B 3 ...
Page 48: ...B 5 JAOP8G BACK VIEW JAOP8G VUE ARRIÈRE B 5 ...
Page 50: ...C 1 SECTION C CONTROL PANELS PANNEAUX DE CONTRÔLE 1PH 120V WITH ZELIO 1PH 120V AVEC ZELIO C 1 ...
Page 51: ...C 2 1PH 120V WITHOUT ZELIO 1PH 120V SANS ZELIO C 2 ...
Page 52: ...C 3 120 208 240V 1PH WITH ZELIO SIMPLE 120 208 240V 1PH AVEC ZELIO SIMPLE C 3 ...
Page 53: ...C 4 120 208 240V 1PH WITHOUT ZELIO SIMPLE 120 208 240V 1PH SANS ZELIO SIMPLE C 4 ...
Page 54: ...SECTION D BURNER ADJUSTEMENTS AJUSTEMENT DU BRÛLEUR NATURAL GAS GAZ NATUREL D 1 ...
Page 55: ...PROPANE GAS GAZ PROPANE D 2 ...
Page 56: ......
Page 57: ......
Page 58: ...NOTES ...