A-17
ECM-1 PROGRAMMABLE CONTROL - OPERATING MODES
The Doyon ECM-1 controller has two operation modes
Manual
and
Programmable.
MANUAL: to use all functions without using recipe program.
PROGRAMMABLE: to use with recipe cook program.
Program capacity
□
Programs #1 to #99 can have up to 10 steps each (low-level programmable).
□
Program #0 is always used as the default Manual Cook mode setting (single-step).
This is the default mode when the controller powers up.
Display/LED
□
Display shows OFF.
□
All other LEDs are off, except the
Start key LED.
Press on
(start) when the oven is ON, the oven will run on preheat mode at the manual mode set
point (except if you select a cook program referred in How to Select a Cook Program or the Manual
Mode section).
To switch the oven OFF Press the RED stop button and hold it for 3 seconds. The oven will run on
cool down mode until it reaches 250°F and then switch OFF.
To change the temperature set point or timer setting press and hold for 3 sec. on
or
. When
appears on the left side of the display, press on
/
(up / down) to select the desired temperature
set point or timer setting. The new set point or time setting will be automatically saved after 3 seconds.
Display/LED
□
Display scrolls current cook program name (by default MANUAL if no program yet selected).
□
2nd line shows actual oven temperature.
□
Heat and Fan, LED follows output state.
□
Ready LED blinks.
□
Stop LED is on.
When probe temperature reaches set point, the unit beeps 5 seconds, the ready LED stays on and the
oven goes into COOK MODE.
When the oven is ON, a 3 second long press of red Stop key will go to Cool Down mode if the oven
temperature is over 250°F / 120°C before going to OFF mode. If the temperature is bellow 250°F /
120°C, the oven goes directly to the OFF mode.
□
If door is opened:
○
Display scrolls DOOR OPEN.
○
All outputs are turned off (unless in Cool Down mode, then fan remains on).
○
All timers pause until the door is closed.
□
When the door is closed, a short delay must expire before all accessories resume normal
operation.
OFF MODE
DOOR SWITCH
Summary of Contents for JA8G
Page 44: ...B 1 SECTION B COMPONENT PARTS PIÈCES COMPOSANTE JAOP8G FRONT VIEW JAOP8G VUE DE FACE B 1 ...
Page 46: ...B 3 JAOP8G RIGHT SIDE VIEW JAOP8G VUE DE CÔTÉ DROIT B 3 ...
Page 48: ...B 5 JAOP8G BACK VIEW JAOP8G VUE ARRIÈRE B 5 ...
Page 50: ...C 1 SECTION C CONTROL PANELS PANNEAUX DE CONTRÔLE 1PH 120V WITH ZELIO 1PH 120V AVEC ZELIO C 1 ...
Page 51: ...C 2 1PH 120V WITHOUT ZELIO 1PH 120V SANS ZELIO C 2 ...
Page 52: ...C 3 120 208 240V 1PH WITH ZELIO SIMPLE 120 208 240V 1PH AVEC ZELIO SIMPLE C 3 ...
Page 53: ...C 4 120 208 240V 1PH WITHOUT ZELIO SIMPLE 120 208 240V 1PH SANS ZELIO SIMPLE C 4 ...
Page 54: ...SECTION D BURNER ADJUSTEMENTS AJUSTEMENT DU BRÛLEUR NATURAL GAS GAZ NATUREL D 1 ...
Page 55: ...PROPANE GAS GAZ PROPANE D 2 ...
Page 56: ......
Page 57: ......
Page 58: ...NOTES ...