A7
INSTRUCTIONS FOR OVEN
BAKING
350
o
F (Croissants, Sweet doughs, Small rolls)
375
o
F (Baguette bread, round loaf, 16 oz. bread and more)
375
o
F (If the oven is filled to its capacity)
Place product in the oven only when the pilot light has gone out.
OPENING AND CLOSING OF THE DOORS
To open the doors: Open one of the doors up to 2" and wait 2 seconds to let the fan reduce its
spinning before opening completely.
To close the doors: Close the first door completely and the second door down to 2" and wait 2
seconds before closing completely and then hold the door closed for 2 seconds.
P.S.
Open the doors as little as possible. This will affect the baking.
COOKING TIMER H5CL
Set the baking time required with the small push button on the timer. The green display is the setting
time and the red display is the countdown time (Ex: 25 minutes = set 2500 on green display).
After setting: Push the
START/STOP
button then, when the time expires, the buzzer will ring. Push
the
START/STOP
button again to stop the buzzer.
If you want to restart the time in the middle of the countdown, press on the yellow
RST
button on the
timer.
P.S.
The timer is simply a reminder for the approximate duration of the baking time.
STEAM TIMER H5CL
Set the steam injection time required with the small push button on the timer. The green display is the
setting time and the red display is the countdown steam time (Ex: 25 seconds = set 2500 on green
display).
To inject steam in the oven, press and release the
START
steam timer button (
while the fan is
running)
to have your setting time steam injection.
If you want to restart the time in the middle of the countdown, press on the
START
button again or
on the yellow
RST
button on the timer.
P.S.
Do not inject steam more than once each time you bake. Wait at least 10 minutes before re-
timing the steam injection system.
Summary of Contents for CA12
Page 22: ...SECTION B DIMENSIONS ...
Page 24: ...B2 41 1 4 54 CA6 CA6 STAND ...
Page 25: ...B3 43 1 2 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET ENTRÉE D EAU Ø1 4 WATER INLET 1 4 CA6 CA6 STAND ...
Page 26: ...B4 LUBRIFICATION DU ROULEMENT À BILLE ANNUELLEMENT BEARING LUBRICATION YEARLY CA6 CA6 STAND ...
Page 28: ...B6 54 76 1 4 CA12 CA12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 33: ...B11 54 76 1 4 CAOP6 CAOP6 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 37: ...B15 54 76 1 4 CAOP12 CAOP12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 40: ...SECTION E COMPONENT PARTS ...
Page 43: ...E3 1 2 3 5 4 CAOP12 CAOP12 ...
Page 45: ...E5 1 2 3 4 9 5 6 7 8 10 CAOP12 CAOP12 ...
Page 47: ...E7 1 2 3 4 5 6 CAOP12 CAOP12 ...
Page 49: ...E9 1 3 2 CAOP12 CAOP12 ...
Page 51: ...E11 1 2 3 4 5 6 16 11 9 7 CAOP6W CAOP6 WATLOW ...
Page 53: ...E13 1 2 3 4 5 6 7 8 13 9 10 11 12 14 CAOP6W CAOP6 WATLOW ...
Page 56: ...SECTION F CONTROL PANELS ...
Page 65: ...SECTION G ELECTRIC SCHEMATICS ...