1.
Turn the switch to the " ON " position. (See next paragraph for the factory-preset program on your
watlow control.)
•
The light inside the oven must light up.
2.
Adjust the WATLOW control at the desired setting (see watlow programming procedure next
page).
Digital display must light up, if not, verify the breaker on the front panel.
3.
Let the oven heat until the set temperature is reached, the LOAD1 red light on the watlow control
will go off when the temperature is stabilized.
4.
Load the oven as fast as possible to avoid letting out too much heat.
5.
Wait until the product is ready before opening doors.
FACTORY PRESET BAKING PROGRAM
MENU # 1 PREHEAT 400°F.
MENU # 2 375°F STEAM 15 SEC., COOKING TIMES 22 MINUTES WITH BUZZER.
MENU # 3 350°F STEAM 15 SEC., COOKING TIMES 25 MINUTES WITH BUZZER.
MENU # 4 325°F NO STEAM, COOKING TIMES 25 MINUTES WITH BUZZER.
325°F (Muffins)
350°F (Croissants, Sweet Doughs, Small rolls)
375
o
F (Baguette bread, round loaf, 16 oz. bread and more)
375
o
F (If the oven is filled to its capacity)
OPENING AND CLOSING OF THE DOORS
To open the doors: Open one of the doors up to 2" and wait 2 seconds to let the fan reduce its
spinning before opening completely.
To close the doors: Close the first door completely and the second door down to 2" and wait 2
seconds before closing completely and then hold the door closed for 2 seconds.
P.S.
Open the doors as little as possible. This will affect the baking.
POWER FAILURE
When the power comes back, the oven will start automatically on the menu #1. Then it is
recommended to turn off the oven to avoid that it starts without supervision.
Summary of Contents for CA12
Page 22: ...SECTION B DIMENSIONS ...
Page 24: ...B2 41 1 4 54 CA6 CA6 STAND ...
Page 25: ...B3 43 1 2 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET ENTRÉE D EAU Ø1 4 WATER INLET 1 4 CA6 CA6 STAND ...
Page 26: ...B4 LUBRIFICATION DU ROULEMENT À BILLE ANNUELLEMENT BEARING LUBRICATION YEARLY CA6 CA6 STAND ...
Page 28: ...B6 54 76 1 4 CA12 CA12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 33: ...B11 54 76 1 4 CAOP6 CAOP6 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 37: ...B15 54 76 1 4 CAOP12 CAOP12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 40: ...SECTION E COMPONENT PARTS ...
Page 43: ...E3 1 2 3 5 4 CAOP12 CAOP12 ...
Page 45: ...E5 1 2 3 4 9 5 6 7 8 10 CAOP12 CAOP12 ...
Page 47: ...E7 1 2 3 4 5 6 CAOP12 CAOP12 ...
Page 49: ...E9 1 3 2 CAOP12 CAOP12 ...
Page 51: ...E11 1 2 3 4 5 6 16 11 9 7 CAOP6W CAOP6 WATLOW ...
Page 53: ...E13 1 2 3 4 5 6 7 8 13 9 10 11 12 14 CAOP6W CAOP6 WATLOW ...
Page 56: ...SECTION F CONTROL PANELS ...
Page 65: ...SECTION G ELECTRIC SCHEMATICS ...