A16
WATLOW PROGRAMMING
The Watlow temperature control can record 12 different menus. It must be programmed before use.
It will save its programs in case of power failure.
Each menu includes 3 "STEPS" and each step includes :
Symbol
•
temperature
SP
•
time
t
•
"EVENT"
E
(steam 0001, auto steam 0100, buzzer 0010 or
no event 0000)
To access the programming mode :
•
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
•
Unlock the read only mode (if necessary), press 12 and "CLOCK", LOC appears. Use the arrows
to get 0 and press "CLOCK" again. (To put back on read only mode, you have to have 1 before
pressing on "CLOCK".)
EXAMPLE 1 (preheat program)
-
For menu #1, we will program it so that we have a preheat time of 20 minutes at 400
°
F followed
by a 15 seconds buzzer.
Step #1
•
Press both arrows simultaneously for 5 seconds. Both lights light up to show that the
programming mode is working.
•
Select the program number (Ex : #1)
Suggested values
SP1 appears.
Use the arrows to adjust to the desired temperature
(400°F)
Press on the number of the menu to confirm
(ex. # 1)
t1 appears
Use the arrows to select the desired timing
(20:00)
Press on the number of the menu to confirm
(ex. # 1)
Summary of Contents for CA12
Page 22: ...SECTION B DIMENSIONS ...
Page 24: ...B2 41 1 4 54 CA6 CA6 STAND ...
Page 25: ...B3 43 1 2 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET ENTRÉE D EAU Ø1 4 WATER INLET 1 4 CA6 CA6 STAND ...
Page 26: ...B4 LUBRIFICATION DU ROULEMENT À BILLE ANNUELLEMENT BEARING LUBRICATION YEARLY CA6 CA6 STAND ...
Page 28: ...B6 54 76 1 4 CA12 CA12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 33: ...B11 54 76 1 4 CAOP6 CAOP6 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 37: ...B15 54 76 1 4 CAOP12 CAOP12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 40: ...SECTION E COMPONENT PARTS ...
Page 43: ...E3 1 2 3 5 4 CAOP12 CAOP12 ...
Page 45: ...E5 1 2 3 4 9 5 6 7 8 10 CAOP12 CAOP12 ...
Page 47: ...E7 1 2 3 4 5 6 CAOP12 CAOP12 ...
Page 49: ...E9 1 3 2 CAOP12 CAOP12 ...
Page 51: ...E11 1 2 3 4 5 6 16 11 9 7 CAOP6W CAOP6 WATLOW ...
Page 53: ...E13 1 2 3 4 5 6 7 8 13 9 10 11 12 14 CAOP6W CAOP6 WATLOW ...
Page 56: ...SECTION F CONTROL PANELS ...
Page 65: ...SECTION G ELECTRIC SCHEMATICS ...