A11
If the OVERHEAT WARNING light is on,
and you hear the warning buzzer.
Check if the cooling fan airflow is not
obstructed.
Check the cooling fan if it is running. If not,
call a qualified technician to replace it.
(Electrical components may be damaged if it is
not repaired immediately.)
OPTIONAL
Manual fill water pan.
The warning red light in the front control
panel stays on when the water pan is full.
You have no more water in the principal water
pan.
Check if the water line is not in air lock
condition. Disconnect the water line at the inlet
of the green solenoid valve and clean the
strainer filter.
Also clean the principal water pan and the float
switch.
If there is no light in the proofer.
1.Verify every breaker in front of the proofer.
2.Verify the main proofer switch and the main
proofer contactor.
If there is no heat in the proofer.
1.Verify every breaker in front of the proofer.
2.Verify whether the pilot light will function by
raising the thermostat to a higher setting. If yes,
verify element. If not, verify pilot light,
thermostat or contactors.
If there is no humidity in the proofer.
Verify whether the pilot light works when you
increase the humidity to the position high. If yes,
verify if water comes in the reservoir and check
the water level switch box and the float switch.
Verify if limestone obstructs the waterflow. If the
float switch is working fine, verify the contactor
P1 and the immersion element. If the pilot light
does not lite, verify the pilot light and the infinite
switch.
Summary of Contents for CA12
Page 22: ...SECTION B DIMENSIONS ...
Page 24: ...B2 41 1 4 54 CA6 CA6 STAND ...
Page 25: ...B3 43 1 2 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET ENTRÉE D EAU Ø1 4 WATER INLET 1 4 CA6 CA6 STAND ...
Page 26: ...B4 LUBRIFICATION DU ROULEMENT À BILLE ANNUELLEMENT BEARING LUBRICATION YEARLY CA6 CA6 STAND ...
Page 28: ...B6 54 76 1 4 CA12 CA12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 33: ...B11 54 76 1 4 CAOP6 CAOP6 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 37: ...B15 54 76 1 4 CAOP12 CAOP12 NOTE GENERAL DIMENSIONS SHOULD BE RESPECTED ...
Page 40: ...SECTION E COMPONENT PARTS ...
Page 43: ...E3 1 2 3 5 4 CAOP12 CAOP12 ...
Page 45: ...E5 1 2 3 4 9 5 6 7 8 10 CAOP12 CAOP12 ...
Page 47: ...E7 1 2 3 4 5 6 CAOP12 CAOP12 ...
Page 49: ...E9 1 3 2 CAOP12 CAOP12 ...
Page 51: ...E11 1 2 3 4 5 6 16 11 9 7 CAOP6W CAOP6 WATLOW ...
Page 53: ...E13 1 2 3 4 5 6 7 8 13 9 10 11 12 14 CAOP6W CAOP6 WATLOW ...
Page 56: ...SECTION F CONTROL PANELS ...
Page 65: ...SECTION G ELECTRIC SCHEMATICS ...