100
A19620 C
Use of the operator interface
You can override the jet recuperation check, i.e. the jet recuperation fault is no longer monitored.
Whenever the printer is stopped, this function goes back to its initial value.
CAUTION
This function should only be used for maintenance purposes,
on an exceptional basis.
Since the printer can operate with different ink bases, in different positions or in different places,
certain parameters have to be entered (ink type, head offset, etc). This "auto-calibration" function
is used for validating these parameters.
CAUTION
This function is only used by the Imaje technician when he
installs the printer or when he carries out after-sales servicing.
This function tells you the pressure, negative pressure and jet speed values together and the
version of the software.
CONTROL JET
RECUPERATION: YES
AUTOCALIBRATION
PRINTER: YES
STATUS OF PRINTER
PARAMETER?