Use of the operator interface
If you validate this function, the printer will stop and you will control all the electrovalves
manually. There are nine electrovalves.
Each time you validate, you are either opening or closing the electrovalve concerned. Check, by
ear, whether the valve is operating properly.
When these checks have been completed, the printer goes into stand-by and you will have to start
it up again by pressing the
p
key.
This function allows you to set an updating index for the printing module (R6 or R7).
To modify this setting, contact Imaje's technical support.
You can override the open cover check, i.e. the check to see whether the cover is open is no longer
made. Whenever the printer is stopped, this function goes back to its initial value.
CAUTION
This function should only be used for maintenance purposes,
on an exceptional basis.
This function is not available for a M head printer with flat
detection electrode.
TEST THE
ELECTROVALVES?
PRINTING
MODULE: R7
OPEN COVER
CONTROL: YES