background image

13/15

NT 201B-A00 04.06 DMX IV Air elimination system e

7.2 CAUSE/SOLUTION/TROUBLESHOOTING

PROCEDURE

Each of the following items describe a single failure
mode. Troubleshoot from high to low probability items.

Before troubleshooting an item, check whether this item
is listed, with the same probability of occurrence, as a
potential cause for another symptom you are not obser-
ving. If yes, place it last in your list of troubleshooting
actions for the given priority and the problem described.

However, when multiple problems occur, troubleshoot
first those items that are listed in each problem trouble
list at the same level of priority.

1/ Air leak on the inlet piping. Check the piping connections.

2/ Vacuum is higher than 4.5" Hg. Reduce the suction

requirements (see the DMX IOM).

3/ Fluid vortexing in the compartment. Install an anti-vor-

tex device at the compartment valve (very rare).

4/ Check and clean the inlet filter strainer (see DMX IOM).

5/ The main float is stuck in the upper position. To check

for this cause, remove the float cover from the DMX
and apply low pressure air to port 1 of the DMX. If
pressure builds up, and the float is not freely moving,
then 5 was involved. Replace the float cover.

6/ The main float is stuck in the lower position. To check

for this cause, remove the float cover from the DMX
and apply low pressure air to port 1 of the DMX. If no
pressure builds up, and the float is not freely moving,
then 6 was involved. Replace the float cover.

7/ Flow detector/check valve installed in the wrong direc-

tion (see Flow Detector IOM).

8/ Flow detector/check valve back pressure is too low.

Increase the back pressure at the check valve. If the
accuracy of this measurement versus the prover is
accurate when not performing a split and stops being
accurate when performing a split, then 8 is the most
probable cause. See the "AIR FREE METERED DELI-
VERING" section of this IOM.

9/ Secondary float sticking in upper position. 

Empty the DMX, and open the compartment valve
with the pump not operating. If no air is vented from
the DMX, then 8, 9 or 26 are the most probable cau-
ses. Check 9 first then 26, then 8. See the DMX IOM
for instruction on disassembly.

10/ The DMX secondary float check valve is sticking in the

upper position.

11/ The DMX secondary float check valve is sticking in the

lower position.

12/ The security chamber is full of liquid. Empty the secu-

rity chamber. See 8 above for the troubleshooting pro-
cedure. See the DMX IOM for instructions on chamber
draining.

13/ The air line from the pneumatic cover to the float cover

is blocked. Replace the air line.

14/ Air leak in the line between the DMX and the Pump

relief valve. Repair or replace the line.

15/ Clogged inlet filter/strainer. Clean or replace the

filter/strainer.

16/ The pneumatic cover is damaged. Replace the cover.

17/ Air leak in the line supplying the air to the DMX top

valve. Repair or replace the line.

18/ Top valve seal is locked in the bottom position. Check

to see if the valve between the secondary float cham-
ber and the security safety is open by removing top
security chamber and trying to push the valve with a
smooth piece. If check valve does not move freely,
replace the top DMX valve.

19/ Leakage inside the pump air  relief valve. Check the

pump  air  relief valve for air leakage. Replace it if
necessary.

20/ Pneumatic line from the flow detector to the air control

panel to the DMX is blocked. Clean or replace the line.

21/ Filter at the air inlet on the DMX pneumatic cover is

dirty or clogged. Clean or replace the filter.

22/ Flow detector pneumatic exhaust is clogged. Clean or

replace the exhaust tube.

23/ Low pressure regulator set too high. Adjust to the

lower setting.

24/ Flow detector out of adjustment or out of order. Adjust

or replace the flow detector.

25/ Air leak between the high pressure regulator in the air

control panel and the flow detector. Repair the air leak.

26/ High pressure regulator is set too low. Adjust to a

higher setting.

27/ Insufficient air supply from the truck.

28/ Engine speed control is out of adjustment.

29/ Verify the DMX air/relief valve assembly is installed on

the pump.

30/ Clogging of the line from the DMX to the pump air

relief valve.

31/ Air line from the Flow Detector to the Air Control Panel

clogged. Clean/replace the air line.

32/ Air line from the ACP to the truck accelerator is clog-

ged. Clean/replace air line.

33/ Failure of the pneumatic distributor in the ACP.

34/ Clogging of the line from the Flow detector to the dis-

tributor inside of the ACP. Clean or replace line.

35/ Flow detector part 961 is stuck in the upper position.

36/ Scavenging line is not installed, or clogged.

37/ Irregular pressure delivered from the high pressure

regulator inside the ACP. Check/replace the high pres-
sure regulator.

38/ Irregular pressure delivered from the low pressure

regulator inside the ACP. Check/replace the low pres-
sure regulator.

7. DMX IV Air Elimination System TROUBLESHOOTING 

(continued)

Summary of Contents for Blackmer DMX IV

Page 1: ...es March 2006 BLACKMER 1809 Century Avenue Grand Rapids Michigan 49503 1530 U S A Telephone 616 241 1611 o Fax 616 241 3752 E mail blackmer blackmer com Internet address www blackmer com BLACKMER ZI PLAINE DES ISLES F 89000 AUXERRE Tel 33 3 86 49 87 13 Fax 33 3 86 49 87 17 e mail contact blackmer mouvex com Original instructions ...

Page 2: ...or personal injury death or major property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property damage NOTICE Indicates special instructions which are very important and must be followed SAFETY INFORMATIONS WARN...

Page 3: ...e serious injury FAILURE TO RELIEVE SYSTEM PRESSU RE PRIOR TO PERFORMING PUMP SERVI CE OR MAINTENANCE CAN CAUSE PER SONAL INJURY OR PROPERTY DAMAGE WARNING Hazardous pressure can cause personal injury or property damage ALL FLUIDS PUMPED MUST BE COMPATI BLE WITH DMX MATERIAL INCOMPATIBI LITY CAN CAUSE FIRE SERIOUS PERSO NAL INJURY OR PROPERTY DAMAGE WARNING Hazardous fluids can cause fire serious ...

Page 4: ...R DMX III AIR ELIMINATION SYSTEM MUST ONLY BE INSTALLED IN SYSTEMS DESIGNED BY QUALIFIED ENGINEERING PERSONNEL SYSTEMDESIGNMUSTCONFORMWITHTOALLAPPLI CABLE REGULATIONSAND CODESAND PROVIDE WARNING OFALL SYSTEM HAZARDS NOTICE THE ENCLOSED IOM APPLY TO DMX III WHERE THEUPGRADE KIT HAVEBEENINSTALLED SEEENCLOSEAVIEWOFTHEUPGRADEKIT The Blackmer DMX IV Air Elimination System is designed for air free deliv...

Page 5: ...f High and Low flowrates Setting of High flowrate Setting of flowrate and engine speed acceleration Air Elimination separation Stop flow when meter is no longer supplied with air free liquid Provide air free and vapor free fluid delivery for metered applications Fluid Control Safety of operation when pumping against closed discharge valve Liquid handling from DMX to Flow Detector Provide strained ...

Page 6: ...r and pump rotational speed to limit the recirculation flowrate through the internal relief valve Some installations will require the limiting of flowrate and or pump discharge pressure For example To reduce the creation of foam in customer tanks To allow easier hose handling during delivery Reduce the setting of the ACP high pressure regulator to reduce the maximum flowrate Check the ACP IOM for ...

Page 7: ...p to be above a given minimum once the system is primed Performance tests have demonstrated that the following pressure settings are typical for operation with DMX and TXD pumps NOTICE IT IS THE INSTALLER S RESPONSIBILITY ON EACH TRUCK TO CHECK THAT THE PUMP BACKPRESSURE IS SUFFICIENT TO ALLOW THE DMX TO PERFORM ITS AIR ELIMINATION FUNC TION PROPERLY ADDING MORE BACKPRESSURE WILL RESULT IN UNACCEP...

Page 8: ... that do not eliminate pressure spikes or pres sure increase due to thermal expansion risks a spare volume of air must be trapped in a dedicated area here after called expansion tank to compress in whenever there is a pressure spike or thermal expansion of trapped liquid The compression of air trapped in the expansion tank will limit the maximum pressure inside DMX to an acceptable level see DMX I...

Page 9: ...P Truck air in connection line marked 1 on Figure 2 this is the same as the first statement in the connections for the ACP and DMX below 2 Connect Line to Engine Speed Control marked 5 on Figure 2 to the feature controlling engine speed Note that if you have 2 DMX Air Elimination Systems installed on the truck and only one truck acceleration system it is allowed to use a shuttle valve to compa re ...

Page 10: ...ystem is also recommended when operating for exten ded periods more than 1 minute against a closed dis charge valve or nozzle 5 12 FLUSHING THE PUMP Refer to the component IOM for flushing procedures and recommendations 5 13 AIR RELIEF VALVE SETTING Set the pump relief valve by adjusting the high pressure regulator in the Air Control Panel For adjustment proce dure refer to Setting of High Flowrat...

Page 11: ...MING SERVICE CAN CAUSE SEVERE PERSONAL INJURY OR PROPERTY DAMAGE WARNING Hazardous machinery can cause severe personal injury or property damage FAILURETODISCONNECTANDLOCKOUT ELECTRICAL POWER OR ENGINE DRIVE BEFORE ATTEMPTING MAINTENANCE CAN CAUSE SEVERE PERSONAL INJURY OR DEATH WARNING Hazardous machinery can cause serious personal injury IF PUMPING HAZARDOUS OR TOXIC FLUIDS THE SYSTEM MUST BE FL...

Page 12: ...es are that the Flow Detector is not returning to its low flow condition or that the Air Control Panel is not functioning properly High probability items 22 33 41 49 Medium probability items 31 32 35 Low probability items 34 44 7 1 6 Low flow rate only The most common root causes are that the Flow Detector is not returning to its low flow condition or that the Air Control Panel is not functioning ...

Page 13: ...ty the secu rity chamber See 8 above for the troubleshooting pro cedure See the DMX IOM for instructions on chamber draining 13 The air line from the pneumatic cover to the float cover is blocked Replace the air line 14 Air leak in the line between the DMX and the Pump relief valve Repair or replace the line 15 Clogged inlet filter strainer Clean or replace the filter strainer 16 The pneumatic cov...

Page 14: ...uirements are not met trapping air 48 Clogged oil separator in the ACP 49 Truck acceleration mechanism is faulty 50 Check all piping connections for leaks 51 DMX overpressurized Potential hammer peak or ther mal expansion condition Install expansion tank to limit the effects of this overall system flaw 52 Low pressure regulator is set too low See the SETTING FLOWRATE AND ENGINE SPEED section of th...

Page 15: ... AUXERRE FRANCE Tél 33 3 86 49 87 13 Fax 33 3 86 49 87 17 Mail contact blackmer mouvex com Site internet www blackmer com 1809 Century Avenue Grand Rapids Michigan 49509 1595 U S A Telephone 616 241 1611 Fax 616 241 3752 E mail blackmer blackmer com Internet Address www blackmer com ...

Reviews: