Model 401 & 403 Pass-Thru
Service and Installation Instructions
99-21972-S001 Rev. C
- 70 -
1
Electrical Information for Normal Temp Doors, Frames & Light Fixtures
(Heater Amperages @ 120 Volts)
NUMBER OF DOORS
1
2
3
4
5
6
7
8
9
10
STYLE:
Normal temp doors with heaters. 3-Pane, Non-Heated Glass
APPLICATION:
Case Temperature: 33
°
F. Relative Humidity: 68%, In-Store @ 75
°
F ambient
23 x 67
0.72
1.45
2.17
2.89
3.62
4.34
5.06
5.78
6.51
7.24
23 x 75
0.81
1.63
2.44
3.26
4.07
4.88
5.70
6.52
7.33
8.14
26 x 67
0.76
1.51
2.27
3.02
3.78
4.54
5.29
6.04
6.81
7.56
26 x 75
0.82
1.64
2.45
3.27
4.09
4.90
5.72
6.54
7.35
8.17
28 x 75
0.88
1.76
2.64
3.52
4.40
5.28
6.16
7.04
7.92
8.80
28 x 79
0.94
1.88
2.82
3.76
4.70
5.64
6.58
7.52
8.46
9.40
30 x 67
0.82
1.64
2.46
3.28
4.10
4.92
5.74
6.56
7.38
8.20
30 x 75
0.87
1.73
2.60
3.47
4.33
5.20
6.07
6.94
7.80
8.67
30 x 79
0.96
1.92
2.88
3.84
4.80
5.76
6.72
7.68
8.64
9.60
11
12
13
14
15
16
17
18
19
20
AMPS/LIGHT
23 x 67
7.95
8.67
9.40
10.12 10.86 11.56 12.31 13.02 13.73 14.48
0.55
23 x 75
8.96
9.78
10.58 11.40 12.21 13.04 13.84 14.66 15.47 16.28
0.55
26 x 67
8.31
9.06
9.82
10.57 11.34
12.08 12.85 13.62 14.35 15.12
0.55
26 x 75
8.99
9.81
10.62 11.44 12.26 13.08 13.89 14.71 15.53 16.35
0.55
28 x 75
9.68
10.56 11.44 12.32 13.20 14.08 14.96 15.84 16.72 17.60
0.55
28 x 79
10.34 11.28 12.22 13.16 14.10 15.04 15.98 16.92 17.86 18.80
0.55
30 x 67
9.02
9.84
10.66 11.48 12.30 13.12 13.94 14.76 15.58 16.40
0.55
30 x 75
9.54
10.41 11.27 12.14 13.01 13.88 14.74 15.61 16.48 17.35
0.55
30 x 79
10.56 11.52 12.48 13.44 14.40 15.36 16.32 17.28 18.24 19.20
0.55
NOTES:
1. All amperages are design amperages subject to the following tolerances: units with rail
heaters only +/- 5%, units with rail heaters and heated glass +/- 8%.
2. Amperages are calculated at 120 volts, but all doors are designed to operate without
sweating when used within the application parameters with a voltage range of +/- 10%.
3. When calculating lamp amperage, add 1 lamp to the number of doors in the line-up
and multiply that number by the appropriate amps per light value
4. Design parameters do not make allowances for air leaks or unusual air flow patterns