background image

  2 

 

Attentions 

1.

 

Don’t expose the camera to rain or moisture (except outdoor     

used model) 

It is designed inside of the house, so be sure to avoid rain and moisture. 

Turn off the power supply and maintain it by qualified person. The 

moisture may affect the cameras and lead to electric risk.. 

2.

 

Don’t aim at the sun 

Be sure not to aim it at the sun or any other bright objects, whether in 

use or not. Alternatively, it may cause the picture unclear.

 

3.

 

Avoid exposing it to the light source or hard light too long 

If the facular appears on the screen due to the light source, the image 

may fade to some extent. 

4.

 

Avoid installing it reversely 

It’s designed for ceiling or wall mount. So if installed upside down, such 

as installing on the floor, it may cause it out of order. 

5.

 

Please use it according to the required temperature and 

humidity

 

Don’t use it under the circumstance of high temperature or humidity. 

Leave it away from heat-generating equipments, such as warm vapor, 

stove and so on.   

6.

 

Placing it away from air-conditioner’s entrance point 

The lens may generate fog due to the water condensing under the 

following circumstance: 

a)

 

Quick changes from high to low temperature caused by     
opening/closing the door occasionally 

b)

 

Used where the glasses can generates fog. 

c)

 

Used in the house full of smog or dust. 

If the lens covered with fog generated by water condensing, put the 

cover down and clean the appearance with a piece of soft cloth. 

7.

 

Consumer Goods 

Some components, such as lens drive motor, cooling fan motor, built-in 

sliding loop may be wear out due to long-term using. Concerning its 

update and maintenance, please consult to maintenance center. 

8.

 

Don’t make it point to the same object too long 

If so, the object’s shadow will appear on the screen. 

 

Summary of Contents for PTZPZ9

Page 1: ...PTZPZ9 Intelligent Integrated IR High Speed Dome Installation Manual Version V1 00 Before using the product please carefully read the manual and the maintenance of this manual for future use...

Page 2: ...statement in order to check when necessary Style number Factory serial number ___________________ The flashing arrow in the symbol is used to remind the user the large non insulated dangerous voltage...

Page 3: ...ation Settings 15 Power on Self Test Display 15 Basic Functions for Menu and Keyboard 15 Menu Hint 17 Main Menu Function Setting 18 System Setting 18 Camera Parameter 21 Pantilt Setting 32 Information...

Page 4: ...maintenance qualified experts should carry it out 7 Do not use it as you like to avoid striking and shocking be sure to use or store it appropriately 8 Please use dry and soft cloth to clean it when i...

Page 5: ...it according to the required temperature and humidity Don t use it under the circumstance of high temperature or humidity Leave it away from heat generating equipments such as warm vapor stove and so...

Page 6: ...P PELCO D 4 ch alarm input 2 ch assisting output Can satisfy practical needs Support auto leisure function Support 8 privacy zones setting in maximum Proportional zoom lens P T speed and depth of zoom...

Page 7: ...settable with easy operation Set 20 main subjects display Built in direction display Built in dome s temperature display Special Use for Preset Point Call 95 PRESET 95 PRESET Enter into main menu Call...

Page 8: ...5 Bracket Installment Size mm IR High Speed Dome Dimension picture 1 Wall Mount Dimension picture 2 Picture 2 Picture 1...

Page 9: ...and its structure Confirmed the ceiling walls brackets must be able to support the installation of the dome and the total weight of the structure Requiring a 4 fold safety factor 3 Preparatory for the...

Page 10: ...or digging hole on the wall and install expansion scre as picture 3 2 Make the cover parts guide line through the bracket to the wall bracket and fix the M5 10 screw gasket then Fix the installed wall...

Page 11: ...8 Dome Setting 1 System Connection 1 Dome System Chart as picture 5 Picture 5 3 DIP Switch Chart as picture 6 Picture 6...

Page 12: ...alarm status relay closed alarm status relay disconnected b 120 Line Setting picture is 120 line setting Jumper setting ON means connected 120 terminal resistance Jumper setting OFF or no jumper line...

Page 13: ...10 DIP Switch Settings Baud rate Setting SW2 B7 B8 Protocol Setting SW2 B1 B6...

Page 14: ...11 Address Setting SW1...

Page 15: ...12...

Page 16: ...13...

Page 17: ...signals before the electricity to work the ball machine as picture 11 Attention Lines should connect strictly obey the chart Picture 11 Color Instruction Red DC12V AC24V Orange Earth line Black DC12V...

Page 18: ...ractice is used by the current movement of equipment and in which the various movements of the function will have no specification details please refer to the manufacturer s user manual for operating...

Page 19: ...en it is in the menu settings It means minish privacy zones up and down during privacy zone edit P T down Camera down rotates move down or change set when it is in the menu settings It means enlarge p...

Page 20: ...TITLE ZOOM POSITION DIRECTION INDICATOR ENVIRONMENTAL INDICATORS GLOBAL SETTING PANTILT SETTING PRESETS SETUP SEQUENCE SETUP PRESETS SETUP AUTOS CAN SETUP HOME ACTION LENS PARAMETER EXPOSURE MODE WHIT...

Page 21: ...d while it is in hard address status Operations 1 Call preset 95 to enter main menu 2 Up down cursor choose SYSTEM SETTING item press OPEN for confirm enter system setting menu 3 Under SYSTEM SETTING...

Page 22: ...directly and no save Instruction 20 characters can be set right pan to skip the no need edition character use black key to replace the need to be deleted character Move pan right to edit the next cha...

Page 23: ...Input New Password shown on the screen twice input the same new password Password Modification Succeed shown on the screen Instruction Dome original password is 000000 Set dome password as 000000 mea...

Page 24: ...fferent manufacturers vary the menu please refer to the corresponding description of the camera feature set LENS PARAMETER Through this menu to set camera s zoom speed electronic zoom and focus and pr...

Page 25: ...oom set parameter flickers 4 Up Down P T to choose 5 Press OPEN to save and exit this item setting Press CLOSE key exit directly and no save FOCUS L IMIT S ETTING Set to limit the focal distance of th...

Page 26: ...es do not support this function IMAGE S TABILIZER In order to prevent image dithering caused by installation environment Operations 1 Call preset 95 to enter main menu 2 Up down cursor to CAMERA PARAM...

Page 27: ...se CAMERA PARAMETERS item press OPEN for confirm enter camera function set menu 3 Under CAMERA PARAMETERS to choose EXPOSURE MODE item press OPEN for confirm enter exposure sub menu set 4 Under EXPOSU...

Page 28: ...exit directly Attention Only under Manual and Iris P mode it is available SHUTTER SPEED SETTING Operations 1 Under EXPOSURE MODE choose SHUTTER SPEED item press OPEN for confirm enter shutter speed s...

Page 29: ...ns 1 Under EXPOSURE MODE choose DIGI SLOW SHUTTER item press OPEN for confirm enter shutter slow set item 2 Up down P T to change shutter slow level value ON OFF means open close this function 3 Press...

Page 30: ...enu 2 Choose CAMERA PARAMETERS item press OPEN for confirm enter camera function set menu 3 Under CAMERA PARAMETERS choose WHITE BALANCE item press OPEN for confirm and enter white balance set item 4...

Page 31: ...item press OPEN for confirm and enter green gain set item 2 Up down P T to change green gain value range from0 255 the larger the number is the blue deeper color turn to cold 3 Press OPEN key save and...

Page 32: ...tatus can this function work WDR MODE This function can brighten the dark image while keeping the bright image as usual and to obtain a more vivid color images at any place Operations 1 Under Camera P...

Page 33: ...erial dome Sony camera can support maximum 8 privacy area the size can be set Masking block will move with dome Remarks 1 This function is associated with built in camera models different camera model...

Page 34: ...t press LEFT narrow window left and right press DOWN enlarge window up and down press UP narrow window up and down 6 Press OPEN key save and exit press CLOSE key exit directly Instruction All the dome...

Page 35: ...parameter set 3 Under PANTILT SETTING choose AUTO FLIP menu press OPEN for confirm and enter auto flip set 4 Up down P T to select and change On means open this function and 90 vertical rotation Off...

Page 36: ...r PANTILT SETTING choose JOYSTICK RECOVER menu press OPEN for confirm and enter rocker recovery set 4 Up down P T to change 5 Press OPEN key save and exit press CLOSE key exit directly SPEED PROPORTIO...

Page 37: ...or confirm and enter pan parameter set 3 Under PANTILT SETTING choose SPEED PROPORTIONAL menu press OPEN for confirm and enter speed matching set 4 Up down joystick to open or close this function pres...

Page 38: ...ing 4 Press CLOSE for return to the upper grade menu Preset Point Setting Menu PANTILT SETTING PRESET POINT SETTING This function could make the dome camera record the current level angel hade angel a...

Page 39: ...characters about the details please refer to the Title Setting of the Dome Camera 3 Press OPEN for confirm save and exit press CLOSE exit directly SET NEW PRESET Operations 1 Call preset point 95 to e...

Page 40: ...t menu 3 Under PANTILT SETTING choose SEQUENCE SETUP and press OPEN for confirm 4 Under SEQUENCE SETUP choose SEQUENCE NUMBER to enter the patrol number change setting and the parameter flicker 5 Up d...

Page 41: ...ill move according to the recorded running track 4 mode functions can be set PANTILT SETTING PATTERN SETUP RECORD NEW PATTERN Operations 1 Call preset point 95 to enter main menu 2 Up Down cursor to c...

Page 42: ...umber Operations 1 Call preset point 95 to enter main menu 2 Up Down cursor to choose PANTILT SETTING press OPEN for confirm and enter pan set menu 3 Under PANTILT SETTING choose AUTOSCAN SETUP and pr...

Page 43: ...able Operations 1 Call preset point 95 to enter main menu 2 Move cursor to choose PANTILT SETTING choose AUTOSCAN SETUP item and press OPEN for confirm to enter scan function set item 3 Under AUTOSCAN...

Page 44: ...N choose HOME ACTION item and press OPEN for confirm and enter into the leisure setting item 2 Up down P T to modify leisure function 1 4 auto scan 1 200 preset point 1 4 patrol 1 4 mode route are sel...

Page 45: ...tion lens multiple indication direction Indication system time and environment index display could be operated at the same time through setting this function Operations 1 Call preset point 95 to enter...

Page 46: ...system 1st is the highest priority the 4th is the lowest priority Dome will automatically in accordance with its high and low priority to receive alarm signal at the same time The alarm input could be...

Page 47: ...cursor to choose ALARMS SETUP item press OPEN for confirm and enter alarm set items 3 Under ALARMS SETUP choose ALARM LINKAGE item press OPEN for confirm 4 Left right P T to change alarm function lin...

Page 48: ...electable Operations 1 Call preset point 95 to enter main menu 2 Up Down cursor to choose ALARMS SETUP item press OPEN for confirm and enter alarm set items 3 Under ALARMS SETUP choose RESET DELAY ite...

Page 49: ...Level speed 0 5 240 seconds adjustable maximum speed Vertical rotation 0 90 Rotation 180 auto rotation Vertical speed 0 5 147 seconds adjustable maximum speed Working environment Temperature 20 C 50 C...

Page 50: ...aged exchange Abnormal auto test chirping sound image display Mechanical failure eliminate Tilt camera Put right Power not exchange Successful auto test but can t control Wrong access control line mod...

Page 51: ...lute prohibition of overhead wiring Strong thunderstorms area or areas of high voltage sensor such as high voltage substations power must be taken to install additional equipment and lightning rod and...

Page 52: ...rs 9600Bps 800meters 3 Connect Method and Terminal Resistance RS485stand requires to use daisy chain connection Two end must connect 120 terminal resistance as picture a simple connection can see pict...

Page 53: ...st diameter is 0 8000mm distance m power VA Line mm 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 4...