9
3)
Jumper Setting (
as picture
7/8
)
Picture 7
Picture 8
a
)
Alarm output relay setting
(
picture
①
is channel 1ala
,
picture
②
is channel 2 alarm output.
)
Jumper setting “NO”: Non-alarm status, relay disconnected
,
alarm
status, relay closed;
Jumper setting “NC”: Non-alarm status, relay closed, alarm status, relay
disconnected.
b
)
120Ω Line Setting
(
picture
③
is 120
Ω
line setting
)
Jumper setting “ON”, means connected 120Ω terminal resistance,
Jumper setting “OFF” or no jumper line means disconnected
120Ωterminal resistance.
Remarks: To avoid the reflection of 485-signal display on the 485 bus
end-point, connect 120Ω termination resistor to the end-point, and the
middle equipment must be disconnected the terminal resistance.