fan 279
status-numeric
uint32
Numeric equivalents for
status
values.
•
0: Up
•
1: Error
•
2: Off
•
3: Missing
speed
uint32
Fan speed (revolutions per minute).
position
string
Fan position, as viewed from the back of the enclosure.
•
Left
•
Right
position-
numeric
uint32
Numeric equivalents for
position
values.
•
0: Left
•
1: Right
serial-number
string
•
(blank): Not applicable.
fw-revision
string
•
(blank): Not applicable.
•
Firmware revision of a fan FRU.
hw-revision
string
•
(blank): Not applicable.
locator-led
string
Shows the state of the locator LED on a fan unit.
•
Off
•
On
locator-led-
numeric
uint32
Numeric equivalents for the
locator-led
property.
•
0: Off
•
1: On
health
string
•
OK
•
Degraded
•
Fault
•
N/A
•
Unknown
health-numeric
uint32
Numeric equivalents for
health
values.
•
0: OK
•
1: Degraded
•
2: Fault
•
3: N/A
•
4: Unknown
health-reason
string
If Health is not
OK
, the reason for the health state.
health-
recommendation
string
If Health is not
OK
, the recommended actions to take to resolve the health issue.
Table 36
fan properties (continued)
Name
Type
Description
Summary of Contents for AssuredSAN 6004
Page 11: ...Document conventions and symbols 11 TIP Provides helpful hints and shortcuts...
Page 114: ...114 Alphabetical list of commands See also set cli parameters show protocols...
Page 139: ...show controller statistics 139 See also reset all statistics reset controller statistics...
Page 162: ...162 Alphabetical list of commands See also show power supplies...