57
LEADING IN PRODUCTION EFFICIENCY
Operating Manual
© Dürr Systems AG
ED3K_Operating_Manual_Rev02LD_03Lug2020_EN. docx
Rev.02 – 03.07.2020
On the USB Stick are created:
-
“EcoDose3K_ConfigData\Configuration” after saving Configuration to USB device,
-
“EcoDose3K_ParamData\Parameters” after saving Parameters to USB device,
-
“EcoDose3K_PurgeData\PurgePrograms” after saving Purge Programs to USB device,
-
“EcoDose3K_RecipeData\Recipes” after saving Recipes to USB device,
-
“EcoDose3K_Consumptions\Consumptions.csv” after saving Consumption to USB device,
-
“E EcoDose3K_Weardata\Wearcounters” after saving the Wear counters to USB device
-
With these files on the USB stick is possible to restore the complete configuration in case of
failure.
The following data will be saved in the configuration files:
-
Number of guns
-
Type of flowmeter
-
Presence of purge air valve
-
Number of color valves
-
Number of hardener valves
-
Presence of EcoGun Cleaner M
-
Presence of pressure regulator
-
Valves output position
-
Serial number
8.5.1.7
Screen cleaning
The screen cleaning can be activated through the following key:
The screen goes black for 15 seconds and all key functions are disabled.
Figure 30 Screen cleaning