Adjust spring force
Secure covers
3.3 Adjust spring force
Fig.11
Increase
Decrease
TS9315
NOTE: Supplied with a size 2 spring setting.
Barrier free openings:
Take an opening force reading
from the pull on the door. If required, adjust the spring
force to meet the barrier-free requirement.
•
Decrease force:
turn counter-clockwise (5 max
turns)
•
Increase force:
turn clockwise (12 max turns)
Depending on opening conditions, a door adjusted to
meet barrier-free forces may not have sufficient power
to reliably close and latch the door.
TS9356
NOTE: Supplied with a size 6 spring setting.
•
Increase force: turn clockwise 6 times (max)
Regular Mount, Pull side closers
Closer size
Max door
weight (lbs)
Door width
Full turns
Interior
Exterior
TS9315
2
100
2'6"
---
0
3
125
3'
2'6"
+3
4
150
3'6"
3'
+9
5
200
4'
3'6"
+12
TS9356
5
200
4'
3'6"
-4
6
250
4'6"
4'
0
4
Install covers
4.1.1
Snap both end covers onto closer body end caps.
4.1.2
Remove un-needed tab, and snap cover over closer body.
4.1.3
Secure with one 4-40 Phillips pan head screw.
4.1.4
Center cover:
Measure distance between track covers,
and subtract 1/2”.
[X - 1-3/16” = center cover length]
4.1.5
Cut center cover to length measured, and slide over
coordinator system.
4.1.6
Snap center caps on to track.
Fig.12
Tab
4-40 pan
head screw
Closer cover
End caps
Center
caps
Center
cover
Track
cover
Track
cover
X