Installing back plate
Installing surface closer
2.1 Installing the back plate
2
Installation instructions
NOTE: Orient pinion closest to hinge.
2.2.1
Secure closer body to plate.
•
Use four M5 x 47mm screws for each closer.
2.2 Installing the surface closer
Fig.4
Fig.3
2.1.1
Secure plate to door.
•
Use four 10-32 x 5/8” PH screws [#10 x 1-1/2”
wood screws] provided for each plate.
NOTE: Ensure arrows point
in direction of arm location.
Left hand door
Right hand
door
Backplate
10-32x5/8"
2.1.2
Secure left and right hand mounting angles to
frame.
•
Use 3 FH screws each.
2.1.3
Cut middle filler angle.
•
Secure using 2 FH screws.
Mounting angles
Mounting angle
flat head screws
Mounting angles
Middle filler angle
Middle filler angle
flat head screws
CUT
NOTE: When cutting filler
angle, be sure to plan for the
conduit hole 5/16”
∅
[8].
Toward the
hinge
Toward the
hinge
Closer
Pinion
Left hand
door
Right hand
door
Pinion