![Dormakaba TENSOR Mounting Instructions Download Page 21](http://html.mh-extra.com/html/dormakaba/tensor/tensor_mounting-instructions_2522928021.webp)
4.4.2 Check the glass door leaf
and the side panel
CAUTION
Risk of injury from broken glass
: cutting/
cutting off the fingers on sharp parts of
broken glass.
Wear protective gloves.
1.
Check glass door leaves for damage,
e.g. glass for conchoidal fractures and/or
damaged edges. Do not install damaged glass
door leaves.
2.
Check the dimensions of glass preparation, see
Fig. 47 on p. 17.
4.4.3 Prepare the double action
hinge
1.
Disassemble the counter plates (Fig. 60/1).
2.
Select the appropriate gaskets (Fig. 60/2)
according to the glass thickness (see Table in
Chapter 4).
3.
Peel off the protection film of the adhesive tape
on the base and counter plate.
Fig. 60
2.
3.
3.
1.
1.
1
1
2
Preparing the double action hinge
4.
Fix the gasket onto the base and counter plate.
4.4.4 Clean glass surfaces
Clean glass surfaces around the clamping areas. Use
commercial glass cleaner. Do not use thinners!
4.4.5 Attach the glass door leaf
to the side panel
ATTENTION
Risk of damage to the glass door leaf by
contact with hard materials (e.g. glass,
metal, concrete)
The contact may cause conchoidal fractures,
damage the edges and/or break the glass
off the glass door. Damaged glass door
leaves should not be installed – risk of injury.
Protect glass edges with spacers!
1.
Horizontally insert the double action hinges in the
glass cutouts in the side panel.
2.
Slightly tighten the counter plates of double
action hinges with the clamping screws.
Fig. 61
1.
2.
Mounting the double action hinge to the side panel
3.
Place the glass door leaf in the mounting position
on wooden blocks or similar objects and align
vertically. Observe the gaps (see Fig. 45 on p.
16).
4.
Screw on the counter plates. Tightening is 15 Nm!
Fig. 62
4.
Mounting the glass door leaf onto the double action
hinge
21
TENSOR
2017-11
WN 059361 45532
dormakaba Mounting instructions
Mounting