![Dormakaba TENSOR Mounting Instructions Download Page 14](http://html.mh-extra.com/html/dormakaba/tensor/tensor_mounting-instructions_2522928014.webp)
1 About these
instructions
1.1 Information about the
instructions
These instructions describe the mounting of TENSOR
double action hinges and provide information on care
and maintenance.
1.2 Target group
Only properly qualified and specially trained staff are
authorized to mount dormakaba glass fittings.
1.3 Symbols used
1.3.1 Safety instructions
Safety instructions are marked with symbols. The
safety instructions are introduced by signal words
that express the extent of the hazard.
Symbol in the
instructions
Signal word
Result
CAUTION
Indicates a potentially
dangerous situation
that can result in
minor injuries if it is
not avoided.
ATTENTION
Indicates a potentially
dangerous situation
that can lead to
property damage if
not avoided.
1.3.2 Further markings
2.
1.
Action steps in graphics
1
2
Position numbers of components
in graphics
1.3.3 Tool icons
Drill
Torque wrench (Item No. 07.624)
Level
3
Allen wrench e.g. wrench size SW 3
2 Safety
2.1 Proper use and foreseeable
misuse
TENSOR double action hinges are only suitable for
vertical installation.
Glass door leaves must not be swung open but must
be guided by hand. The glass door closes
automatically. The reset mechanism can cause
operational sounds. The glass door leaf must not be
pushed open. The maximum door opening angle of
double action doors is 90° in each opening direction.
Double action doors must be protected from greater
opening angles on site, e.g. by using a doorstop.
Fig. 35
Double action door with on-site doorstops in any
opening direction
TENSOR double action hinges are not suitable for
single action doors.
Fig. 36
Incorrect use as a single action door
2.1.1 Specifications for the
installation location
TENSOR double action hinges are only suitable for dry
indoors spaces.
TENSOR double action hinges are not suitable for
showers, sauna, bath or salt-water bath applications
or rooms where chemicals (e. g. chlorine) are used.
Fig. 37
Not suitable for showers, sauna, bath or salt-water
bath
14
TENSOR
2017-11
WN 059361 45532
dormakaba Mounting instructions
About these instructions