3.2.3.1 Scope of delivery
‣ 2 x double action hinge (Fig. 46/ 1)
‣ Gaskets side panel each 4 x in 3 different thickness
levels: 1 mm, 2 mm, 3 mm (Fig. 46/ 2)
‣ Gaskets glass door leaf each 4 x with 3 various
thickness levels: 1 mm, 2 mm, 3 mm (Fig. 46/ 3)
‣ 12 x cover cap in 3 different
colors (Fig. 46/ 4)
Fig. 46
1
2
3
4
Scope of delivery of the glass to glass mounting|
3.2.3.2 Size of glass preparations
Glass height GH = LH - 10 mm
Glass width GW = LW - 6 mm
Fig. 47
Glass preparations for the glass to glass mounting
3.2.3.3 Tools for mounting
‣ Level
‣ Allen wrench, wrench size SW 3, 4, 5
‣ Torque wrench (Item No. 07.624)
4 Mounting
4.1 Determine the thickness of
the gasket
The following applies for all product variants:
Depending on the glass thickness, the suitable
gaskets must be selected and used according to the
following table.
Glass thickness
12 mm
10 mm
8 mm
Gaskets
1 mm
2 mm
3 mm
4.2 Wall mounting with surface
mounted mounting plate
4.2.1 Check the glass door leaf
CAUTION
Risk of injury from broken glass
: cutting/
cutting off the fingers on sharp parts of
broken glass.
Wear protective gloves.
1.
Check the glass door for damage, e.g. glass for
conchoidal fractures and/or damaged edges. Do
not install damaged glass door leaves.
2.
Check the dimensions of glass preparation, see
Fig. 41 on p. 16.
4.2.2 Prepare the double action
hinge
1.
Disassemble the counter plate (Fig. 48/1).
2.
Select the appropriate gaskets (Fig. 48/2)
according to the glass thickness (see Table in
Chapter 4).
3.
Peel off the protection film of the adhesive tape
on the base and counter plate (Fig. 48/1 and Fig.
48/3).
Fig. 48
2.
3.
1.
1
2
3
Preparing the double action hinge
4.
Fix the gasket onto the base and counter plate.
17