4.3.5 Attach the double action
door hinge to the frame
1.
Attach double action hinges with countersunk
screws M8 x 16 to the prepared frame.
2.
Tightening is 20 Nm.
Fig. 57
Mounting double action hinges into the frame
4.3.6 Clean glass surfaces
Clean glass surfaces around the clamping areas. Use
commercial glass cleaner. Do not use thinners!
4.3.7 Position and screw in double
action hinges
ATTENTION
Risk of damage to the glass door leaf by
contact with hard materials (e.g. glass,
metal, concrete)
The contact may cause conchoidal fractures,
damage the edges and/or break the glass
off the glass door.
Damaged glass door leaves should not be
installed – risk of injury. Protect glass edges
with spacers!
1.
Place the glass door leaf at the mounting position
on wooden blocks or similar objects.
2.
Mount counter plates. Tightening is 15 Nm.
3.
Remove all assembly blocks.
Fig. 58
2.
3.
1.
Mounting the glass door leaf
4.4 Glass to glass mounting
4.4.1 Mount the side panel
ATTENTION
Risk of damage to the glass door leaf by
inadequate, unstable mounting
The side panel must be attached in a
sufficiently stable manner. A simple silicone
seam for the bottom attachment is
insufficient!
Use dormakaba wall connection profile or
dormakaba U-profile!
dormakaba recommends using the dormakaba wall
connection profile part no.: 07.050/051/052 (Fig.
59/2). For the lower edge of the side panel, we
recommend using the Dorma U-profile part no.:
07.093 (Fig. 59/1).
1.
Check the side panel for damage, e.g. conchoidal
fractures and/or damaged edges. Do not install a
damaged side panel.
2.
Mount the side panel according to the enclosed
mounting instructions.
Fig. 59
1
2
Mounting the side panel
20
TENSOR
2017-11
WN 059361 45532
dormakaba Mounting instructions
Mounting