SafeRoute® System
2019-03
WN 059722 45532
dormakaba System manual
Annex
12 Annex
SLI
Mini
SLI
Basic
SLI
Standard
Release
Via emergency button (with alarm trigger)
○
○
○
Unlock
Via key switch(without alarm trigger)
– Temporary unlocking
○
○
●
– Long-term unlocking
-
-
●
– Permanent unlocking
○
○
○
– Operating time of the key switch for triggering the
unlocking type long-term permanent unlocking
-
-
●
– Combination function short-term, long-term, permanent
unlocking: one of the different unlocking types can be deactivated
-
-
●
Automatic unlocking at defined times of day (timer)
-
-
●
By alarm system (fire, danger, smoke detectors, sprinklers, etc.)
○
○
○
Bi-directional escape route
-
○
○
From outside to inside via external analog ST (key switch)
○
●
●
From outside to inside via external DCW® ST or SVP / M-SVP 22xx
-
●
●
Lock
Automatic relocking
– After temporary unlocking
○
○
●
– After long-term unlocking
-
-
●
– If door was not opened after pressing the emergency button
1)
-
●
●
– After closing
-
-
●
Automatic locking at defined times of day (timer)
-
-
●
Automatic relocking after power cut
○
○
○
Resetting the unlocking via key/emergency button
○
●
●
Direct connection of motor locks
SVP 2xxx DCW®/ M-SVP 22xx DCW®
-
●
●
Vis./Aud. display
Status/Warning/Initialization display on the illuminated ring.
– Adjusting the brightness
-
●
●
– Adjusting the flashing frequencies
-
-
●
Pre-alarm/main alarm after temporary unlocking and
long-term unlocking
○
○
●
Maintenance alarm
○
○
●
Acoustic confirmation when activating
long-term or permanent unlocking
○
○
●
Alarm duration limit
○
●
●
Alarm management (activation/deactivation of alarms)
-
●
●
Monitoring
Tamper monitoring (can be deactivated for maintenance purposes)
●
●
●
“Door open” monitoring
○
○
●
Two different time ranges for
the “door open” monitoring’s pre-alarm and main alarm
-
-
●
Entry control
Access control via keypad, e.g. STD-UP touchscreen display
-
-
●
History memory with date and time stamp
-
-
○
Networking
LON
-
●
●
LAN
-
○
○
Miscellaneous
Automatic reactivation after power cut
○
○
○
Parameterization/visualization/control via TMS Soft®
-
●
●
Freely programmable inputs/outputs on the SCU
-
●
●
Additional programmable inputs/outputs via SIO-DR or I/O DCW®
-
-
●
Application cards
SLI-A
Multi-door control
-
■
■
Interlock control
-
■
■
Logic functions
-
-
■
Time-Delayed Release
1)
-
■
■
– one time delay step (parameterizable)
-
■
■
-
not available
○
available, not parameterizable
●
available and parameterizable
■ with app
1)
EN 13637 function