42
ED50
01-2020
DL4615-001
dormakaba ED50 Installation Instructions – Fine cover
Chapter 12
12.4 Remove mounting plate from ED50 operator
Fig. 12.4.2 Mounting plate removed from ED50 operator
12.4.1 Remove 115 Vac plug from
receptacle.
1. Remove 115 Vac plug (
5
) from its
receptacle (
6
).
12.4.2 Remove mounting plate from
operator.
1. Loosen all eight captive ED50 M6 socket
head cap screws (SHCS) using a 5 mm
hex T-handle.
TIPS AND RECOMMENDATIONS
Insure all eight fasteners are free
of the mounting plate.
2. Remove operator from mounting plate.
TIPS AND RECOMMENDATIONS
Guide pin resistance may require
screwdriver to start operator
removal from end of mounting
plate (Fig. 12.4.3).
Fig. 12.4.1 115 Vac plug removal
Fig. 12.4.3 Mounting plate removal
Fig. 12.4.4 5 mm T-handle
hex key
5
Guide pin
1
ED100 / ED250
operator
2
Mounting base
3
M6 X 20 SHCS
4
M6 X 10 SHCS
5
Guide pin
6
115 Vac plug
5
115 Vac plug
6
115 Vac socket
5
6
5
6
1
3
3
4
4
5
6
5