Flow Chart for UNIFORM BUILDING CODE
N
Y
LEDR Blinking Fast
Local Alarm On
Remote Alarm On
Buzzer Pulsing
Nuisance Delay
Time Out ?
Dip Switch Setting
Dip1-
On: 15 Seconds
Dip2/Dip3- Off/On: 2 Seconds.
Dip4-
On.
Power On
Locked ?
Door Pushing ?
LEDR Off
LEDG Blinks every 5S.
Local Alarm Off
Remote Alarm On
Y
N
Y
LEDR Blinking Slowly
Local Alarm On
Remote Alarm Off
Buzzer On
Release Delay
Time Out ?
Y
LEDR/G Blinking Alt.
Local Alarm Off
Remote Alarm Off
Lock Release
N
Still Locked ?
N
LEDR On
Local Alarm Off
Remote Alarm Off
Reset to Relock
?
Y
Relock
N
Y
Dip1-
Release Delay 15
seconds only.
Dip2/Dip3- Nuisance delay must be
set 2 seconds.
Relock occurs only when Reset
Switch Input from open to close.
NOTE:
NOTE:
N
Buzzer Off
Buzzer Off
Flow Chart for BOCA
N
Y
LEDR Blinking Fast
Local Alarm On
Remote Alarm On
Buzzer Pulsing
Nuisance Delay
Time Out ?
Dip Switch Setting
Dip1-
On: 15 Sec. Off: 30 Sec.
Dip2/Dip3- On/Off: 1 Second.
Dip4-
Off.
Power On
Locked ?
Door Pushing ?
LEDR Off
LEDG Blinks every 5S.
Local Alarm Off
Remote Alarm Off
Y
N
Y
LEDR Blinking Slowly
Local Alarm On
Remote Alarm Off
Buzzer On
Release Delay
Time Out ?
Y
LEDR/G Blinking Alt.
Local Alarm Off
Remote Alarm Off
Lock Release
N
Still Locked ?
N
LEDR On
Local Alarm Off
Remote Alarm Off
Relock Delay
Starts ?
Y
Relock
N
Y
Dip1-
Release Delay can be
15 or 30 seconds.
Dip2/Dip3- Nuisance delay must be
set at 1 second.
30 seconds Relock Delay starts only
when Reset Switch Input from open
to close. At this stage, door close.
NOTE:
NOTE:
N
Dip4-
Relock Delay required
set at 30 seconds.
Y
Relock Delay
Stops ?
N
30 seconds Relock Delay stops only
when Reset Switch Input from close
to open. At this stage, door open.
NOTE:
Y
Relock Delay
T/O ?
N
Buzzer Off
Buzzer Off