Book 22772784 (9/08/06)
39
COMPRESSOR CODE 11
Too Many Start Attempts During Auto Start
Explanation:
The WEDGE has made three attempts to start the machine as commanded by
the Auto Start Stop controller. The machine failed to start.
Effect:
Code 11 is a SHUTDOWN condition and will shutdown the machine.
TROUBLESHOOTING STEPS
Code 11
Action
Result
Step1:
Check the machine fuel system and engine fuel filters.
Step 2:
Check the condition of the machine batteries.
Step 3:
Cycle machine power, activate the Auto Start input so the
machine will make another start attempt. Machine will go
through 3 crank cycles to attempt start before a Code 11 is
issued.