COMPRESSOR CODE 50
Separator Tank Temperature
Explanation:
The WEDGE has received a separator tank temperature from RT1 that is
greater than 247 degrees F.
Effect:
Code 50 is a shutdown condition and will shutdown the machine.
TROUBLESHOOTING STEPS
Code 50
Action
Result
Step1:
Check for package air inlet restrictions.
Step 2:
Check for dirty or clogged coolers.