80
( )
Book No. 22772784 (9--8--06)
HP1300/1600WCU Electrical Manual
CHART E1
CIRCUIT TROUBLESHOOTING
CIRCUIT DESCRIPTION
PT1
SEPARATOR TANK
PRESSURE TRANSDUCER
P1--8 BRN
P1--7 ORN
PT1 SEPARATOR TANK
PRESSURE CIRCUIT
J1--8
J1--7
J1--10
P1--10 VIO
A
C
B
5VDC+
SIG (+)
GND
The WEDGE reads separator tank pressure from PT1. It is a gauge pressure
transducer mounted on the separator tank. The WEDGE provides 5 VDC excitation
voltage to pin B (+5) and pin A (GND). The pressure signal on pin C connects to the
WEDGE input. The signal range is .45 to 4.5 volts. The transducer range is 0 to 225
psig.
To check the operation of PT1, connect a known correct gage in parallel with it.
Compare readings and if PT1 does not track the test gage, replace it. This test
should be performed from idle to loaded engine speeds. The test gauge used
should be at least 1% accuracy to match the accuracy of PT1.
WEDGE
CONTROLLER
W099
W098
W101
W1
HARNESS
Summary of Contents for 25/300
Page 2: ...2...
Page 19: ...17 Book No 22772784 9 8 06 HP1300 1600WCU Electrical Manual SECTION 3 SERVICE TOOLS...
Page 69: ......
Page 70: ...22742951 Control System Wiring Diagram 22742951_071_06 04_A...
Page 71: ......
Page 72: ...22742951 Control System Wiring Diagram 22742951_072_06 04_A...
Page 73: ......
Page 74: ...22742951 Control System Wiring Diagram 22742951_073_06 04_A...
Page 75: ......
Page 76: ...22742951 Control System Wiring Diagram 22742951_074_06 04_A...
Page 77: ......
Page 78: ...22742951 IQ Wiring Diagram 22742951_074_06 04_A...
Page 79: ......
Page 101: ...93 Book No 22772784 9 8 06 HP1300 1600WCU Electrical Manual...
Page 102: ...94 Book No 22772784 9 8 06 HP1300 1600WCU Electrical Manual...
Page 106: ...98 Book No 22772784 9 8 06 HP1300 1600WCU Electrical Manual SECTION 9 ELECTRICAL PARTS LIST...
Page 116: ...108 Book No 22772784 9 8 06 HP1300 1600WCU Electrical Manual SECTION 12 Software Information...