Verify that the piping from the orifice purge points to the exhaust system is not
clogged.
CAUTION
!
Blockage of the Y-strainers, orifices, or piping can result in flooding of
the vessels with condensate. If flooding occurs, excessive condensate
may enter the air stream and could result in damage to downstream
equipment.
Yearly Maintenance:
The normal maintenance interval on the primary and secondary IQ System filters is one year,
or earlier if pressure drop becomes excessive. Restriction indicators for the filters are mounted
on the filter support inside the front door, and will shut down the compressor if restriction
exceeds recommended values.
CAUTION
!
Excessively restricted filter elements may cause an increase in the
amount of aerosol water and oil carryover, which could result in damage
to downstream equipment. Normal service intervals should not be
exceeded.
Filter Replacement
•
With engine stopped, ensure pressure is relieved from air system.
•
Remove all wires and hoses connected to drains on bottom of each filter housing.
Inspect fittings and hoses for any blockage. Clean if necessary.
•
Using a chain wrench or similar tool, loosen the housing. The housing should be
removed by hand after loosening, taking care to prevent the housing from falling to
the floor panel.
•
Lower the housing to floor panel and lean it against the airend. Remove and replace
the filter element, being careful not to damage outer wrap.
Verify the part number of new element vs. old element, as the two IQ filters are of
different media.
•
Put a small amount of petroleum jelly or other non-synthetic grease on the element
O-Ring to aid installation into the filter head.
•
Replace housing making sure to not overtighten.
•
Repeat the above procedure on the remaining filter element.
•
Reconnect all wires and hoses to drains on bottom of each filter housing.
Summary of Contents for 10/370
Page 2: ...2...
Page 6: ...6...
Page 7: ...7 Foreword...
Page 8: ...Operating Maintenance Manual Foreword 8 Add in PDF Page for CE Mark...
Page 11: ...11 Safety...
Page 19: ...Safety Operating Maintenance Manual 19...
Page 20: ...Operating Maintenance Manual Safety 20...
Page 21: ...Safety Operating Maintenance Manual 21...
Page 23: ...Safety Operating Maintenance Manual 23...
Page 26: ...Operating Maintenance Manual Safety 26...
Page 27: ...27 Noise Emission...
Page 33: ...33 General Data...
Page 36: ...36...
Page 37: ...37 Operating Instructions...
Page 52: ...52...
Page 53: ...53 Maintenance...
Page 66: ...66...
Page 67: ...67 Lubrication...
Page 71: ...71 Troubleshooting...
Page 82: ...82...
Page 83: ...83 Electrical...
Page 88: ...88...
Page 89: ...89 Electrical Schematics...
Page 90: ...Operating Maintenance Manual Electrical Schematics 90...
Page 91: ...Electrical Schematics Operating Maintenance Manual 91...
Page 92: ...Operating Maintenance Manual Electrical Schematics 92...
Page 93: ...Electrical Schematics Operating Maintenance Manual 93...
Page 94: ...94...